Leveling in Reverse

IMPORTANT: To avoid bending the bucket cutting edge on a solid object while leveling in reverse, position the bucket less than 40° below level. Use FLOAT to reduce down pressure.

1. Position bucket 40° or less below level.

2. When possible, use "FLOAT" to reduce down pressure on bucket.

3. Back up slowly.

W01786

OUO6038,000192F -19-11APR03-1/1