The following values are adjustable for the E-ICV (Electronic
Independent Control Valve) extend and retract functions:
-
CAUTION: Avoid injury or death from objects falling on operator.
Activate loader function on page two or set all shutoff times to zero.
An inactive or zero shutoff time prevents the loader from unexpectedly
raising to full height if a lever is unintentionally moved to detent
position.
IMPORTANT: Before operating a front loader, make sure that none
of the detent positions have programmed time limits. The E-ICV must
be set for LOADER. See Additional Functions of the Electronic Selective
Control Valves in the tractor operator's manual for more detail.
Press button (B). Use selection wheel (A) to select (highlight)
ICV (C) and press check mark (Confirm) button to display E-ICV Front
Valve screen.
-
Select (highlight) and confirm next page (D).
-
Select loader symbol (E) and activate with confirm button.
-
Select return (F) symbol. A loader symbol appears in bottom
left corner of screen and shutoff times (J) disappear.
-
NOTE: If cell (G) is active, adjustments for ICV extend and
retract functions are independent. If cell (H) is active, adjustments
for ICV extend and retract functions are synchronized and identical.
Use selection wheel to highlight Independent Control (G) or
Synchronized Control (H) and press Confirm button.
-
CAUTION: Avoid injury or machine damage caused by excessive
flow rates. Full extension and retraction of cylinders must take at
least 2 seconds.
NOTE: Flow rate is adjustable in increments of 0.1. The minimum
is 0.2 and the maximum is 10.
Highlight a flow control (I) entry, press the confirm button,
adjust flow rate with selection wheel, and press confirm button.
-
Repeat extend and retract adjustments for remaining entries.