IMPORTANT: Hardware torque MUST be checked after the first 10
hours and every 50 hours thereafter.
Check mounting frame hardware. (See FIRST 10 HOURS in Lubrication
and Maintenance section.)
-
Lubricate all grease fittings. (See Lubrication and Maintenance
section.)
-
IMPORTANT: 5X03 Series Tractors: Exhaust pipe might contact
loader hydraulic hoses. Muffler assembly may have to be repositioned
to prevent damage to tractor or loader.
Start tractor engine and check loader operation.
-
IMPORTANT: Perform operation check at least three times to help
remove air from hydraulic lines.
Cycle all cylinders at least three times as follows:
-
Extend lift cylinders and lift bucket from ground.
-
Retract bucket cylinders (roll back) and lower to the ground.
-

W08640-UN-18MAY07

W08641-UN-18MAY07
A - Clamp
B - Cap Screws, Muffler-to-Engine
C - Hardware, Exhaust Pipe-to-Muffler (4 used)
D - Cap Screw
5X03 Series Tractors: Check for
clearance between exhaust pipe and loader hydraulic hoses when raising
and lowering loader. If hydraulic hoses contact exhaust pipe, perform
the following:
-
Lower loader to the ground, shut off tractor engine and remove
key.
-
Wait until muffler and engine cools down.
-
Loosen hardware (A—D).
-
Push muffler toward turbocharger and tighten clamp (A).
-
Tighten hardware (B) to specification.
-
Tighten hardware (C) to specification.
| Item | Measurement | Specification |
|
Muffler-to-Engine Cap Screws (B) | Torque | 70 N·m (52 lb-ft) |
|
Exhaust Pipe-to-Muffler Hardware (C) | Torque | 35 N·m (26 lb-ft) |
-
Tighten cap screw (D).
-
Repeat steps 3—5 as necessary.
-
Retract bucket cylinders completely and lower loader to ground.
-
Shut off tractor engine and remove key.
-
Check tractor transmission/hydraulic oil level. (Refer to tractor
Operator's Manual.)