In the case of manual spraying, the spraying pressure must be adjusted as follows in order to spray a specific quantity in liters/hectare:
1.
In the spray volume table (see "Adjusting the nozzle output" in this section), find the output per nozzle in l/min, at the desired application rate per hectare and the driving speed in km/h, and divide this value by 2 (on account of the nozzle spacing of 25 cm).
2.
Find the spraying pressure in the table with which this output is obtained for the fitted metering disc. Disc CP4916-40 is the standard disc.
3.
Multiply the spraying pressure found with the density of the liquid (for AHL 1.28 kg/l). Determine the density by weighing exactly 1 liter.
4.
Determine the pressure loss (see "Adjusting the nozzle output" in this section) between pressure
|
gauge and the pressure piece on the drop hose with the liquid fertilizer. The pressure loss is also dependent on the liquid viscosity.
When working with a spraying computer, the liquid output can be set to working with liquid fertilizers as described in the relevant section. If the computer works with a pressure sensor, the density correction factor must be programmed and activated. In addition, the nozzle spacing must be set to 25 cm. If the computer works with a flow sensor, no correction is necessary for the application rate control, but necessary for displaying the correct (calculated) liquid pressure.
Spraying table metering discs for drop hoses
|