Cleaning
IMPORTANT:
If the machine is cleaned with a high pressure system (be careful to avoid paint damage), the lubricating nipples must be greased before and after cleaning. Do not apply a high pressure cleaner to electrical components and first cover them with plastic.
IMPORTANT:
Before cleaning the machine, first check the label, package or safety instructions of the chemical if special rinsing procedures or special cleaning agents are required.
Besides the system cleaning, which must take place after each spray job (Refer to "Cleaning the Machine" in the section "Working with the Machine", "Rinse Tank" or "Ring Line Circulation System" in the section entitled "Operation of the machine"), there are also components which must be regularly cleaned such as the optional transfer valve (refer to "Transfer Valve To Pump Liquid Back To Store", "External Pump Filling Connection" or "Ecomatic Filling System" in the section "Accessoires").
The pressure line filter must be cleaned at least after every spray job. Very soiled filters lead to increased wear and a reduction of the pump capacity, thus reducing the spraying pressure. Also refer to "Control Group" in the section "Operation of the Machine".