Tank Rinsing System

To clean the solution tank internally, proceed as follows:

  • Set the four-way suction valve of the spraying pump to "suction of rinse water" (or for sprayers with automatic filling, set the electric filling valve(s) and the manual suction valve(s) to "suction of rinse water") and set the pressure selection valve to "tank rinsing". The circulation valve must be in the "circulation" position.
  • Turn off the master shut-off valve and then turn on the pump. The solution tank will now be cleaned internally. Keep the solution tank cover closed during rinsing of the tank.

The rotating tank rinsing nozzles each have 3 split shaped holes facing in various directions so that they spray water on all the tank walls.

A line filter (A) is fitted in the supply line to the rinsing heads. This filter must be cleaned regularly. The 100 mesh filter has a mesh width of 150 micron (0.15 mm).

WZ290101676


A-Line filter

WZ00085,0000321 -19-12APR05-1/1