Replacing Coolant With JD COOL-GARD Coolant

Replacing Coolant (3215 and 3415)

causym CAUTION: Remove expansion tank cap (A) only when coolant temperature is below boiling point. Then loosen cap to relieve pressure before removing the cap completely.

NOTE: The service interval for replacing engine coolant must be reduced to 2000 hours/2 years when John Deere Cool-Gard is not used.

1. Remove expansion tank cap (A).

2. Remove radiator drain plug (B).

3. Remove coolant drain plug (C) from engine block.

4. Drain the coolant into a suitable container.

5. As soon as system is empty, re-install drain plugs and fill the system with a commercial cooling system cleaning solution.

6. Run engine until it reaches operating temperature. Shut off engine and drain cooling system.

7. Re-install drain plugs again and fill the system with clean water.

IMPORTANT: Never pour cold water or coolant into the hot engine. Always use warm water or wait until engine has cooled down.

8. Again run engine until it has reached operating temperature. Shut off engine and drain system again.

9. Re-install drain plugs again, and this time fill the system with the specified coolant (see Section "Fuel, Lubricants, Coolant and Capacities").

Specification

Cooling system -Total Capacity 21.5 liters (6 US. gal.)

ZX1036964
ZX1036983
ZX1036984


A-Tank cap
B-Radiator drain plug
C-Engine drain plug

OUCC020,0002044 -19-29MAR05-1/4


10. When filling is completed, run the engine. This will allow the thermostat to open, ensuring that coolant is circulated throughout the entire cooling system.

11. Recheck coolant level. Coolant level should be between MAX and MIN levels. If necessary top up with the specified coolant.

12. For efficient cooling, the radiator screen must be kept clean. Remove any dust or oil and carefully straighten any bent fins.

OUCC020,0002044 -19-29MAR05-2/4


Replacing Coolant (3220 and 3420)

causym CAUTION: Remove expansion tank cap (A) only when coolant temperature is below boiling point. Then loosen cap to relieve pressure before removing the cap completely.

NOTE: The service interval for replacing engine coolant must be reduced to 2000 hours/2 years when John Deere Cool-Gard is not used.

1. Remove expansion tank cap (A).

2. Remove radiator drain plug (B).

3. Remove coolant drain plug (C) from engine block.

4. Drain the coolant into a suitable container.

5. As soon as system is empty, re-install drain plugs and fill the system with a commercial cooling system cleaning solution.

6. Run engine until it reaches operating temperature. Shut off engine and drain cooling system.

7. Re-install drain plugs again and fill the system with clean water.

IMPORTANT: Never pour cold water or coolant into the hot engine. Always use warm water or wait until engine has cooled down.

8. Again run engine until it has reached operating temperature. Shut off engine and drain system again.

9. Re-install drain plugs again, and this time fill the system with the specified coolant (see Section "Fuel, Lubricants, Coolant and Capacities").

Specification

Cooling system -Total Capacity 35 liters (9 US. gal.)
Cooling radiator -Capacity 5.8 liters (1.53 US. gal.)
Cooling Expansion Tank -Capacity 2.8 liters (0.73 US. gal.)

ZX1033827
ZX1033869
ZX1033870


A-Tank cap
B-Radiator drain plug
C-Engine drain plug

OUCC020,0002044 -19-29MAR05-3/4


10. When filling is completed, run the engine. This will allow the thermostat to open, ensuring that coolant is circulated throughout the entire cooling system.

11. Recheck coolant level. Coolant level should be between MAX and MIN levels. If necessary top up with the specified coolant.

12. For efficient cooling, the radiator screen must be kept clean. Remove any dust or oil and carefully straighten any bent fins.

OUCC020,0002044 -19-29MAR05-4/4