Codes for Digital Display and Forward Stability Indicator (Load Monitor) |
Definition |
01 |
Digital Display Voltage Supply Under 8 V |
02 |
Digital Display Voltage Supply Over 16 V |
11 |
Forward Stability Indicator Sensor Under Current (Disconnected) |
12 |
Forward Stability Indicator Sensor Over Current (Short Circuit) |
13 |
Forward Stability Indicator Sensor Input Out of Range (High/Low), Damaged Sensor/Wiring |
14 |
Forward Stability Indicator Sensor Calibration Error (Cal Values out of range), Bad Calibration |
21 |
Weighing Device Sensor Under Current (Disconnected) |
22 |
Weighing Device Sensor Over Current (Short Circuit) |
23 |
Weighing Device Sensor Input Out of Range (High/Low), Damaged Sensor/Wiring |
24 |
Weighing Device Sensor Calibration Error (Cal Values out of range), Bad Calibration |
31 |
Non-volatile Memory Checksum Error |
41 |
Transmission Data Error (No Clock Signal) |
42 |
Transmission Data Error (No Data Signal) |
43 |
Transmission Data Error (Unknown Code) |
51 |
Real Time Clock Error (No Time Advance) |
52 |
Real Time Clock Error (Illegal Time Setting) |
|
|
Codes for TCU |
Definition |
61 |
Error Forward Low |
62 |
Error Forward High |
63 |
Error Reverse |
64 |
Error Clutch 1 |
65 |
Error Clutch 2 |
66 |
Error Clutch 3 |
67 |
Error in ROM memory |
68 |
Error in RAM memory |