Digital Display and TCU (Transmission Control Unit), Diagnostic Trouble Codes

The two asterisks (A) at digital display indicate an error sensed by the following control units:

  • Digital Display
  • TCU (Transmission Control Unit) Power Shift only

To access the diagnostic trouble codes see "Setting Digital Display" in "Controls and Instruments" Section.

See diagnostic trouble code list and definition hereafter.

Diagnostic Trouble Code Definition
ZX1037021

Codes for Digital Display and Weighing Device Definition
01 Voltage Supply Under 8V
02 Voltage Supply Over 16V
21 Weight Sensor Under Current (Disconnected)
22 Weight Sensor Over Current (Short Circuit)
23 Weight Sensor Input Out of Range (High/Low), Damaged Sensor/Wiring
24 Weight Sensor Calibration Error (Cal Values out of range), Bad Calibration
31 Non-volatile Memory Checksum Error
41 Transmission Data Error (No Clock Signal)
42 Transmission Data Error (No Data Signal)
43 Transmission Data Error (Unknown Code)
51 Real Time Clock Error (No Time Advance)
52 Real Time Clock Error (Illegal Time Setting))
   
Codes for TCU Definition
61 Error Forward Low
62 Error Forward High
63 Error Reverse
64 Error Clutch 1
65 Error Clutch 2
66 Error Clutch 3
67 Error in ROM memory
68 Error in RAM memory

 

OUCC020,000210F -19-04MAY05-1/1