C03 - Cornerpost Control Unit Diagnostic Trouble Codes

Control Unit SPN FMI Pri. Description
C03 63 09 3 CAN Bus message missing from control unit E13 (VCM) - feed rate.
First check diagnostic address C03 133 and switch off the feed rate option if the latter is not installed.
C03 96 09 3 CAN Bus message missing from right control unit - fuel level.
C03 110 09 3 CAN Bus message missing from engine control unit - coolant temperature.
C03 190 09 3 CAN Bus message missing from engine control unit - engine speed.
C03 627 03 3 Delayed power supply (circuit 006) › voltage is too high (greater than 16 VDC).
C03 628 12 1 Controller cannot exit boot block program. Disconnect cornerpost control unit connector X500. Reconnect connector. Replace cornerpost control unit if condition persists.
C03 630 11 1 EEPROM failed test at power up. Replace cornerpost control unit if condition persists.
C03 639 19 3 CAN Bus messages are not being transmitted or received correctly. Possible effects are none, slow response, or machine down.
C03 1079 03 3 Concave position sensor supply voltage too high - greater than 5.5 VDC.
C03 1079 04 3 Concave position sensor supply voltage too low - less than 4.5 VDC.
C03 1486 03 3 Concave position sensor voltage too high - greater than 4.5 VDC. Faulty sensor or wiring.
C03 1486 04 3 Concave position sensor voltage too low - less than 0.5 VDC. Faulty sensor or wiring.
C03 1487 03 3 Dimmer voltage is too high - greater than 4.5 VDC. Faulty device or wiring.
C03 1487 04 3 Dimmer voltage is too low - less than 0.5 VDC. Faulty device or wiring.
C03 1492 08 3 Cab interior backlighting output transistor detects an open, short, over voltage, or over temperature condition. The cornerpost control unit will turn off the backlighting. The fault condition must be removed before the backlighting can be turned on.
C03 1493 09 3 CAN Bus message missing from master tailings sensor - tailings volume.
C03 1500 11 3 A switch on cornerpost display unit 1 is closed for longer than 30 seconds.
C03 1501 11 3 A switch on cornerpost display unit 2 is closed for longer than 30 seconds.
C03 1502 11 3 A switch on cornerpost display unit 3 is closed for longer than 30 seconds.
C03 1503 09 3 CAN Bus message missing from armrest control unit - armrest switch status.
C03 1510 09 3 CAN Bus message missing from right control unit - temperatures on combine.
C03 1511 09 3
l
CAN Bus message missing from right control unit - grain loss.
C03 1515 09 3 CAN Bus message missing from header control unit - header data.
C03 1552 03 3 CLIMATRAK temperature setpoint adjust voltage too high - greater than 4.5 V DC. Faulty device or wiring.
C03 1552 04 3 CLIMATRAK temperature setpoint adjust voltage too low - less than 0.5 V DC. Faulty device or wiring.
C03 1552 13 3 CLIMATRAK temperature setpoint adjust not calibrated.
C03 1553 03 3 CLIMATRAK fan speed adjust voltage too high - greater than 4.5 V DC. Faulty device or wiring.
C03 1553 04 3 CLIMATRAK fan speed adjust voltage too low - less than 0.5 V DC. Faulty device or wiring.
C03 1553 13 3 CLIMATRAK fan speed adjust not calibrated.
C03 1565 09 3 CAN Bus message missing from armrest control unit - separator and header engage status.

 

ZX08994,00000BC -19-21SEP06-1/2


Control Unit SPN FMI Pri. Description
C03 1567 09 3 CAN Bus message missing from header control unit - control mode.
C03 100100 09 3 CAN Bus message missing from left control unit - system data.
C03 100101 09 3 CAN Bus message missing from left control unit 2 - system data.
C03 100106 11 3 A switch on cornerpost display unit 4 is closed for longer than 30 seconds.

 

ZX08994,00000BC -19-21SEP06-2/2