SIG Addresses - Metal Detector Control Unit

SIG - Metal Detector Control Unit
Addresses  
Number Type Description
002 Standard System Beep Mode
003 Standard Limited System Beep Mode
004 Standard Analog Beep Mode
005 Standard Digital Beep Mode
010 Analog Input Z-X Level Voltage
Display in Volts
011 Analog Input X-Y Level Voltage
Display in Volts
012 Analog Input Y-Z Level Voltage
Display in Volts
013 Analog Input Sensor Reference Voltage
Display in Volts
014 Analog Input Sound Sending Unit A Voltage
Display in Volts
015 Analog Input Sound Sending Unit B Voltage
Display in Volts
016 Analog Input Battery Voltage
Display in Volts
017 Analog Input Battery Voltage 2
Display in Volts
080 Display Sensor Threshold Display
Display in mV
If the sensor voltage exceeds this value, the metal detector control unit will trip.
081 Display Quick Stop Counter
Used to display the number of times that feed roll forward is stopped due to quick stop.
082 Display Metal Detector Trip Counter
Used to display the number of times the metal detector has tripped.
083 Display Knock Level of Sound Sending Unit A
Used to display the knock level of sound sending unit A (accumulation over 20 ms).
Read only address.
084 Display Knock Level of Sound Sending Unit B
Used to display the knock level of sound sending unit B (accumulation over 20 ms).
Read only address.
085 Display Knock Rate of Sound Sending Unit A
Used to display the knock rate of sound sending unit A (actual value after 20 ms).
Read only address.
086 Display Knock Rate of Sound Sending Unit B
Used to display the knock rate of sound sending unit B (actual value after 20 ms).
Read only address.
087 Display Emergency Mode Counter
Used to display the number of times the metal detector is switched to emergency mode.

 

OUCC002,0000083 -19-11OCT05-1/3


SIG - Metal Detector Control Unit
Addresses  
Number Type Description
088 Display Sound Sending Unit A Average Knock Level
Used to display the average knock level of sound sending unit A. The average knock level is used to determine if sound sending unit is connected.
089 Display Sound Sending Unit B Average Knock Level
Used to display the average knock level of sound sending unit B. The average knock level is used to determine if sound sending unit is connected.
100 Interactive Calibration Metal Detector Engage
Used to engage the metal detector simultaneously when the main clutch is engaged.

NOTE: For detailed calibration procedure, see "Address SIG 100 Calibration - Metal Detector Engage" in this section.

101 Input Calibration Sensor Initial Threshold
Used to set the sensor initial threshold voltage in mV.
The initial threshold voltage corresponds to sensor sensitivity height:
Value: 925 mV is ~ 150 mm (5.9 in.)
Value: 1500 mV is ~ 90 mm (3.5 in.)
Value: 2000 mV is ~ 80 mm (3.1 in.)
Value: 2500 mV is ~ 70 mm (2.7 in.)
Display:
SIG
101
2000

Default setting: 2000 mV

IMPORTANT: The maximum value cannot exceed 3500 mV.

102 Interactive Calibration Failed Stop Pawl Override
Used to override a failed stop pawl condition.

NOTE: For detailed calibration procedure, see "Address SIG 102 Calibration - Failed Stop Pawl Override" in this section.

104 Input Calibration Control Options (Operator)
Used to calibrate the operator control options.
The eighth digit from the left determines if Automatic Lubrication System is installed.
1 - Indicates automatic lubrication system is installed...XXXX
...XXX1
0 - Indicates automatic lubrication system is not installed...XXXX
...XXX0

 

OUCC002,0000083 -19-11OCT05-2/3


SIG - Metal Detector Control Unit
Addresses  
Number Type Description
105 Interactive Calibration Automatic Lubrication On Time Calibration
Used to set the on time for the automatic lubrication system in minutes.

NOTE: For detailed calibration procedure, see "Address SIG 105 Calibration - Automatic Lubrication System On Time" in this section.

106 Interactive Calibration Automatic Lubrication Off Time Calibration
Used to set the off time for the automatic lubrication system in minutes.

NOTE: For detailed calibration procedure, see "Address SIG 106 Calibration - Automatic Lubrication System Off Time" in this section.

139 Input Calibration Disable 676/678 Header Processing
This address disables processing of 676 or 678 header related inputs.
0 - Enables 676/678 header processing
1 - Disables 676/678 header processing
198 Display - Operator
Calibration - Factory
Enable Metal Detector Override Counter
199 Display - Operator
Calibration - Factory
Pawl Override Counter

 