| SPF - SPFH Main Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 002 |
Standard |
System Beep Mode |
| 003 |
Standard |
Limited System Beep Mode |
| 004 |
Standard |
Analog Beep Mode |
| 005 |
Standard |
Digital Beep Mode |
| 006 |
Standard |
Frequency Beep Mode |
| 010 |
Analog Input |
Header Up Valve Current Display in Amperes |
| 011 |
Analog Input |
Header Down Valve Current Display in Amperes |
| 015 |
Analog Input |
Fuel Level Voltage Display in Volts |
| 016 |
Analog Input |
Header Lift Pressure Sensor Voltage Display in Volts |
| 017 |
Analog Input |
Pressure Sensor Power Voltage Display in Volts |
| 018 |
Analog Input |
Header Angle Sensor Voltage Display in Volts |
| 019 |
Analog Input |
IVLOC PWM Current Display in Amperes |
| 020 |
Analog Input |
Battery Voltage Display in Volts |
| 021 |
Analog Input |
Sharpening Potentiometer Power Voltage Display in Volts |
| 022 |
Analog Input |
Sharpening Door Potentiometer Voltage Display in Volts |
| 023 |
Analog Input |
Stone Position Potentiometer Voltage Display in Volts |
| 024 |
Analog Input |
Hydraulic Oil Temperature Sensor Voltage Display in Volts |
| 025 |
Analog Input |
Hydrostatic Oil Temperature Sensor Voltage Display in Volts |
| 070 |
Frequency |
Feed Roll Speed Displays the feed roll speed measured in rpm. |
| 071 |
Frequency |
Wheel Speed Displays the wheel speed measured in rpm. |
| 072 |
Frequency |
Cutterhead Speed Displays the cutterhead speed measured in rpm. |
| 080 |
Display |
Default Sharpening Sweep Counter |
| 081 |
Display |
Current Sharpening Sweep Counter |
| 082 |
Display |
Sharpening Door Position |
| SPF - SPFH Main Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 083 |
Display |
Sharpening Stone Position |
| 084 |
Display |
Kernel Processor Clearance Left Motor |
| 085 |
Display |
Kernel Processor Clearance Right Motor |
| 086 |
Display |
Stored Engine Speed To Cutterhead Speed Ratio |
| 087 |
Display |
Calculated Engine Speed To Cutterhead Speed Ratio |
| 088 |
Display |
Left Stationary Knife Motor Sensor Counter The counter will be reset each time any stationary knife movement process begins. |
| 089 |
Display |
Right Stationary Knife Motor Sensor Counter The counter will be reset each time any stationary knife movement process begins. |
| 090 |
Display |
Left Kernel Processor Motor Sensor Counter The counter will be reset each time any kernel processor movement process begins. |
| 091 |
Display |
Right Kernel Processor Motor Sensor Counter The counter will be reset each time any kernel processor movement process begins. |
| 092 |
Display |
Header Position Upper Limit The upper position limit is defined during the header calibration process. |
| 093 |
Display |
Header Position Lower Limit The lower position limit is defined during the header calibration process. |
| 094 |
Display |
Header Pressure Upper Limit The upper pressure limit is defined during the header calibration process. |
| 100 |
Input Calibration |
Header Calibration Used to manually calibrate the header type and the upper and lower header limits for the automatic header control system.NOTE: For detailed calibration procedure, see "Address SPF 100 Calibration - Header" in this section. |
| 101 |
Interactive Calibration |
Control The Kernel Processor Clearance With Input Control Knob Used to control the kernel processor clearance with input control knob.NOTE: For detailed calibration procedure, see "Address SPF 101 Calibration - Control The Kernel Processor Clearance With Input Control Knob" in this section. |
| 102 |
Interactive Calibration |
Header Raise Rate Used to calibrate the manual and return to position header raise rate.NOTE: For detailed calibration procedure, see "Address SPF 102 Calibration - Header Raise Rate" in this section. |
| 103 |
Interactive Calibration |
Header Lower Rate Used to calibrate the manual and return to position header lower rate.NOTE: For detailed calibration procedure, see "Address SPF 103 Calibration - Header Lower Rate" in this section. |
| 104 |
Input Calibration |
Control Options (Operator) Used to calibrate the operator control options. The third digit from the left controls the Header Height Accumulator. 1 - Indicates that the header height accumulator is disabled...XX1X ...XXXX 0 - Indicates that the header height accumulator is enabled...XX0X ...XXXX |
| SPF - SPFH Main Control Unit |
| Addresses |
|
| Number |
Type |
Description |
104 Continuation |
Input Calibration |
The sixth digit from the left determines if a Cutterhead Sharpening Door is installed. 1 - Indicates a door is installed...XXXX ...X1XX 0 - Indicates a door is not installed...XXXX ...X0XXNOTE: If the cutterhead sharpening door is not installed, the SPFH control unit ignores all requests to control the door and disables the generation of all door related DTCs. |
104 Continuation |
Input Calibration |
The seventh digit from the left determines if the Kernel Processor Control is activated. 1 - Indicates an electrically controlled kernel processor is installed...XXXX ...XX1XNOTE: If the seventh digit from the left is set to 1, the SPFH control unit allows to adjust the kernel processor clearance from the cab and will also force the third digit from the left to a value of 1 to enable monitoring of the cutterhead belt.0 - Indicates an electrically controlled kernel processor is not installed...XXXX ...XX0X NOTE: If the seventh digit from the left is set to 0, the SPFH control unit does not allow to adjust the kernel processor clearance from the cab. |
104 Continuation |
Input Calibration |
The eighth digit from the left indicates if an Automatic Lubrication System is installed. 1 - Indicates the auto lubrication system is installed...XXXX ...XXX1 0 - Indicates the auto lubrication system is not installed...XXXX ...XXX0NOTE: If the auto lubrication system is installed, the SPFH main control unit sends the status of the auto lubrication system in a CAN status message. |
| 105 |
Input Calibration |
Number Of Cutterhead Knifes Used to read and set the number of knives installed on the cutterhead.NOTE: For detailed calibration procedure, see "Address SPF 105 Calibration - Number Of Cutterhead Knifes" in this section. |
| 106 |
Input Calibration |
Kernel Processor Initial Clearance Used to read and set the current kernel processor clearance in mm. The clearance can be set in the following steps:- 0.25 mm (0.0098 in.) from 1 up to 5 mm (0.039 - 0.196 in.)
- 1 mm (0.039 in.) from 5 up to 10 mm (0.196 - 0.39 in.) for wide cutterhead
- 1 mm (0.039 in.) from 5 up to 20 mm (0.196 - 0.78 in.) for standard cutterhead
|
| SPF - SPFH Main Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 108 |
Interactive Calibration |
Sharpening Door Closed Position Used to read and set the closed position of the sharpening door. Viewing this address will display the current calibrated closed position.NOTE: The sixth digit from the left in "Address SPF 104" must be set to 1 to reach the "Sharpening Door Closed Position" address. |
| 109 |
Interactive Calibration |
Sharpening Door Open Position Used to read and set the open position of the sharpening door. Viewing this address will display the current calibrated open position.NOTE: The sixth digit from the left in "Address SPF 104" must be set to 1 to reach the "Sharpening Door Open Position" address. |
| 110 |
Interactive Calibration |
Sharpening Stone Direction Check Used to verify the sharpening stone motor is wired correctly. Viewing this address will display Ston. |
| 111 |
Interactive Calibration |
Sharpening Stone Home Position Used to read and set the park position of the sharpening stone. Viewing this address will display the current calibrated park position. |
| 112 |
Interactive Calibration |
Sharpening Stone Left Cutterhead Position Used to read and set the left cutterhead position of the sharpening stone. |
| 113 |
Interactive Calibration |
Sharpening Stone Right Cutterhead Position Used to read and set the right cutterhead of the sharpening stone. |
| 114 |
Interactive Calibration |
Sharpening Stone Advance Position Used to read and set the advance position of the sharpening stone. |
| 115 |
Input Calibration |
Minimum Cutterhead Speed For Harvesting Used to read and set the minimum cutterhead speed for harvesting. |
| 118 |
Interactive Calibration |
Sharpening Stone Wear Used to check the sharpening stone wear and set the sharpening stone limit position.NOTE: For detailed calibration procedure, see "Address SPF 118 Calibration - Sharpening Stone Wear" in this section. |
| 198 |
Display - Operator |
Cutterhead Operating Time |
| 199 |
Display - Operator |
Machine Operating Time |