SPF Addresses - SPFH Main Control Unit

SPF - SPFH Main Control Unit
Addresses  
Number Type Description
002 Standard System Beep Mode
003 Standard Limited System Beep Mode
004 Standard Analog Beep Mode
005 Standard Digital Beep Mode
006 Standard Frequency Beep Mode
010 Analog Input Header Up Valve Current
Display in Amperes
011 Analog Input Header Down Valve Current
Display in Amperes
015 Analog Input Fuel Level Voltage
Display in Volts
016 Analog Input Header Lift Pressure Sensor Voltage
Display in Volts
017 Analog Input Pressure Sensor Power Voltage
Display in Volts
018 Analog Input Header Angle Sensor Voltage
Display in Volts
019 Analog Input IVLOC PWM Current
Display in Amperes
020 Analog Input Battery Voltage
Display in Volts
021 Analog Input Sharpening Potentiometer Power Voltage
Display in Volts
022 Analog Input Sharpening Door Potentiometer Voltage
Display in Volts
023 Analog Input Stone Position Potentiometer Voltage
Display in Volts
024 Analog Input Hydraulic Oil Temperature Sensor Voltage
Display in Volts
025 Analog Input Hydrostatic Oil Temperature Sensor Voltage
Display in Volts
070 Frequency Feed Roll Speed
Displays the feed roll speed measured in rpm.
071 Frequency Wheel Speed
Displays the wheel speed measured in rpm.
072 Frequency Cutterhead Speed
Displays the cutterhead speed measured in rpm.
080 Display Default Sharpening Sweep Counter
081 Display Current Sharpening Sweep Counter
082 Display Sharpening Door Position

 

OUCC002,00020E9 -19-03NOV05-1/5


SPF - SPFH Main Control Unit
Addresses  
Number Type Description
083 Display Sharpening Stone Position
084 Display Kernel Processor Clearance Left Motor
085 Display Kernel Processor Clearance Right Motor
086 Display Stored Engine Speed To Cutterhead Speed Ratio
087 Display Calculated Engine Speed To Cutterhead Speed Ratio
088 Display Left Stationary Knife Motor Sensor Counter
The counter will be reset each time any stationary knife movement process begins.
089 Display Right Stationary Knife Motor Sensor Counter
The counter will be reset each time any stationary knife movement process begins.
090 Display Left Kernel Processor Motor Sensor Counter
The counter will be reset each time any kernel processor movement process begins.
091 Display Right Kernel Processor Motor Sensor Counter
The counter will be reset each time any kernel processor movement process begins.
092 Display Header Position Upper Limit
The upper position limit is defined during the header calibration process.
093 Display Header Position Lower Limit
The lower position limit is defined during the header calibration process.
094 Display Header Pressure Upper Limit
The upper pressure limit is defined during the header calibration process.
100 Input Calibration Header Calibration
Used to manually calibrate the header type and the upper and lower header limits for the automatic header control system.

NOTE: For detailed calibration procedure, see "Address SPF 100 Calibration - Header" in this section.

101 Interactive Calibration Control The Kernel Processor Clearance With Input Control Knob
Used to control the kernel processor clearance with input control knob.

NOTE: For detailed calibration procedure, see "Address SPF 101 Calibration - Control The Kernel Processor Clearance With Input Control Knob" in this section.

102 Interactive Calibration Header Raise Rate
Used to calibrate the manual and return to position header raise rate.

NOTE: For detailed calibration procedure, see "Address SPF 102 Calibration - Header Raise Rate" in this section.

103 Interactive Calibration Header Lower Rate
Used to calibrate the manual and return to position header lower rate.

NOTE: For detailed calibration procedure, see "Address SPF 103 Calibration - Header Lower Rate" in this section.

104 Input Calibration Control Options (Operator)
Used to calibrate the operator control options.
The third digit from the left controls the Header Height Accumulator.
1 - Indicates that the header height accumulator is disabled...XX1X
...XXXX
0 - Indicates that the header height accumulator is enabled...XX0X
...XXXX

 

OUCC002,00020E9 -19-03NOV05-2/5


SPF - SPFH Main Control Unit
Addresses  
Number Type Description
104
Continuation
Input Calibration The fourth digit from the left determines if the SPF control unit monitors the Tension of the Kernel Processor Belt.
1 - Indicates that a belt tension system is installed and the SPF control unit monitors the belt tension and controls Powr-Savr and main clutch requests accordingly...XXX1
...XXXX
0 - Indicates a belt tension system is not installed...XXX0
...XXXX
104
Continuation
Input Calibration The fifth digit from the left determines if the Automatic Header Control System will move the other position Preset Value when the current preset value is too close to the other preset value.
1 - Allows the other preset value to move...XXXX
...1XXX
0 - Does not allow the other position preset to move...XXXX
...0XXX

 

OUCC002,00020E9 -19-03NOV05-3/5


SPF - SPFH Main Control Unit
Addresses  
Number Type Description
104
Continuation
Input Calibration The sixth digit from the left determines if a Cutterhead Sharpening Door is installed.
1 - Indicates a door is installed...XXXX
...X1XX
0 - Indicates a door is not installed...XXXX
...X0XX

NOTE: If the cutterhead sharpening door is not installed, the SPFH control unit ignores all requests to control the door and disables the generation of all door related DTCs.

104
Continuation
Input Calibration The seventh digit from the left determines if the Kernel Processor Control is activated.
1 - Indicates an electrically controlled kernel processor is installed...XXXX
...XX1X

NOTE: If the seventh digit from the left is set to 1, the SPFH control unit allows to adjust the kernel processor clearance from the cab and will also force the third digit from the left to a value of 1 to enable monitoring of the cutterhead belt.0 - Indicates an electrically controlled kernel processor is not installed...XXXX
...XX0X

NOTE: If the seventh digit from the left is set to 0, the SPFH control unit does not allow to adjust the kernel processor clearance from the cab.

104
Continuation
Input Calibration The eighth digit from the left indicates if an Automatic Lubrication System is installed.
1 - Indicates the auto lubrication system is installed...XXXX
...XXX1
0 - Indicates the auto lubrication system is not installed...XXXX
...XXX0

NOTE: If the auto lubrication system is installed, the SPFH main control unit sends the status of the auto lubrication system in a CAN status message.

105 Input Calibration Number Of Cutterhead Knifes
Used to read and set the number of knives installed on the cutterhead.

NOTE: For detailed calibration procedure, see "Address SPF 105 Calibration - Number Of Cutterhead Knifes" in this section.

106 Input Calibration Kernel Processor Initial Clearance
Used to read and set the current kernel processor clearance in mm.
The clearance can be set in the following steps:0.25 mm (0.0098 in.) from 1 up to 5 mm (0.039 - 0.196 in.)1 mm (0.039 in.) from 5 up to 10 mm (0.196 - 0.39 in.) for wide cutterhead1 mm (0.039 in.) from 5 up to 20 mm (0.196 - 0.78 in.) for standard cutterhead

 

OUCC002,00020E9 -19-03NOV05-4/5


SPF - SPFH Main Control Unit
Addresses  
Number Type Description
108 Interactive Calibration Sharpening Door Closed Position
Used to read and set the closed position of the sharpening door.
Viewing this address will display the current calibrated closed position.

NOTE: The sixth digit from the left in "Address SPF 104" must be set to 1 to reach the "Sharpening Door Closed Position" address.

109 Interactive Calibration Sharpening Door Open Position
Used to read and set the open position of the sharpening door.
Viewing this address will display the current calibrated open position.

NOTE: The sixth digit from the left in "Address SPF 104" must be set to 1 to reach the "Sharpening Door Open Position" address.

110 Interactive Calibration Sharpening Stone Direction Check
Used to verify the sharpening stone motor is wired correctly.
Viewing this address will display Ston.
111 Interactive Calibration Sharpening Stone Home Position
Used to read and set the park position of the sharpening stone.
Viewing this address will display the current calibrated park position.
112 Interactive Calibration Sharpening Stone Left Cutterhead Position
Used to read and set the left cutterhead position of the sharpening stone.
113 Interactive Calibration Sharpening Stone Right Cutterhead Position
Used to read and set the right cutterhead of the sharpening stone.
114 Interactive Calibration Sharpening Stone Advance Position
Used to read and set the advance position of the sharpening stone.
115 Input Calibration Minimum Cutterhead Speed For Harvesting
Used to read and set the minimum cutterhead speed for harvesting.
118 Interactive Calibration Sharpening Stone Wear
Used to check the sharpening stone wear and set the sharpening stone limit position.

NOTE: For detailed calibration procedure, see "Address SPF 118 Calibration - Sharpening Stone Wear" in this section.

198 Display - Operator Cutterhead Operating Time
199 Display - Operator Machine Operating Time

 

OUCC002,00020E9 -19-03NOV05-5/5