RCP - Corner Post Control Unit Diagnostic Trouble Codes

RCP - Corner Post Control Unit Diagnostic Trouble Codes
Control Unit SPN FMI Pri. Indicator Light Description Effect
RCP 158 00 2   Battery Voltage High. Control unit shutdown, functions not available.
RCP 158 01 2   Battery Voltage Low. Control unit shutdown, functions not available.
RCP 628 12 2   Program Memory Failure. Control unit functions not available.
RCP 630 12     No Factory / Dealer Settings. Initial calibration cannot be called back with the reset switch.
RCP 1500 11 2   Corner Post Switch Matrix. One or probably several switches of the corner post do not work correctly.
RCP 1552 03   Air temperature control Temperature Set Point Potentiometer High. Temperature setting not possible.
RCP 1552 04   Air temperature control Temperature Set Point Potentiometer Low. Temperature setting not possible.
RCP 1552 13 3 Air temperature control Temperature Set Point Potentiometer Not Calibrated. Temperature setting not possible.
RCP 1553 03   Air temperature control Blower Setting Potentiometer High. Blower setting not possible.
RCP 1553 04   Air temperature control Blower Setting Potentiometer Low. Blower setting not possible.
RCP 1553 13 3 Air temperature control Blower Setting Potentiometer Not Calibrated. Blower setting not possible.
RCP 1563 12 2   Incompatible Control Unit. No control unit function is available.
RCP 300400 09 2   Metal Detector Control Unit Not Communicating. Metal detector control unit functions not available, harvesting operations not possible.
RCP 300401 09 2   Armrest Control Unit Not Communicating. Corner post control unit functions not available.
RCP 300402 09 2   SPFH Main Control Unit Not Communicating. SPFH main control unit functions not available, harvesting operations not possible.
RCP 300403 09 2   Overhead Control Panel Control Unit Not Communicating. Overhead control panel control unit functions not available.
RCP 300404 09 2   Rear Wheel Drive Control Unit Not Communicating. Rear wheel drive disabled.

 

OUCC002,0002103 -19-08NOV05-1/2


RCP - Corner Post Control Unit Diagnostic Trouble Codes
Control Unit SPN FMI Pri. Indicator Light Description Effect
RCP 300405 09 2   Row Guidance Control Unit Not Communicating. Row guidance control unit disabled.
RCP 300406 03     Backlight Dimmer Potentiometer High. Default backlight to on.
RCP 300406 04     Backlight Dimmer Potentiometer Low. Default backlight to on.
RCP 300406 13 3   Backlight Dimmer Potentiometer Not Calibrated. Default backlight to on.
RCP 300407 09 2   TMC 190 Control Unit Not Communicating.  

 

OUCC002,0002103 -19-08NOV05-2/2