ARC Addresses - Armrest Control Unit
|
|
| ARC - Armrest Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 002 |
Standard |
Beep Mode |
| 003 |
Standard |
Limited System Beep Mode |
| 004 |
Standard |
Analog Beep Mode |
| 005 |
Standard |
Digital Beep Mode |
| 080 |
Display |
Cab Temperature |
| 081 |
Display |
Outlet Temperature |
| 082 |
Display |
Inlet Temperature |
| 083 |
Display |
Evaporator Temperature |
| 100 |
Input Calibration |
Spout Fast Rotate Delay Configuration Used to set the spout fast rotate delay.NOTE: For detailed calibration procedure, see "Address ARC 100 Calibration - Spout Fast Rotate Delay Configuration" in this section. |
| 101 |
Input Calibration |
Fast Throttle Speed Used to set the fast throttle increase / decrease speed of the engine. |
| 102 |
Input Calibration |
Slow Throttle Speed Used to set the slow throttle increase / decrease speed of the engine. |
| 103 |
Input Calibration |
Slow Throttle Speed Hold Time Used to set the time the slow throttle speed engine acceleration is active before the high throttle engine speed acceleration becomes active. |
| 104 |
Input Calibration |
Button 1 Configuration Used to select the function for button 1 on the multi-function lever.NOTE: For detailed calibration procedure, see "Address ARC 104 Calibration - Button 1 Configuration" in this section. |
| 105 |
Input Calibration |
Button 2 Configuration Used to select the function for button 2 on the multi-function lever.NOTE: For detailed calibration procedure, see "Address ARC 105 Calibration - Button 2 Configuration" in this section. |
| 106 |
Input Calibration |
Button 3 Configuration Used to select the function for button 3 on the multi-function lever.NOTE: For detailed calibration procedure, see "Address ARC 106 Calibration - Button 3 Configuration" in this section. |
| 107 |
Input Calibration |
Circular Button Configuration Used to select the function for the row guidance enable switch / selective control valve I on the multi-function lever.NOTE: For detailed calibration procedure, see "Address ARC 107 Calibration - Circular Button Configuration" in this section. |
|
|
OUCC020,0001EC1 -19-17OCT05-1/3
|
| ARC - Armrest Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 108 |
Input Calibration |
Control Options (Operator) Used to calibrate the operator control options. The fifth digit from the left enables Automatic Output Mode for SCV II and Wagon Dump. 1 - Enables automatic output mode...XXXX ...1XXX 0 - Disables automatic output mode...XXXX ...0XXXNOTE: In auto output mode, a double click turns on the output which will remain on even when the button is released. Address ARC 109, ARC 111, ARC 112 and ARC 113 defines the time-out period for the output. The sixth digit from the left MUST remain unchanged .
The seventh digit from the left enables Automatic Actuation Raise. 1 - Indicates the automatic actuation. Drives the SCV I + (raise) output when the metal detector trips...XXXX ...XX1X 0 - Disables Automatic Actuation Raise...XXXX ...XX0X
The eighth digit from the left enables Automatic Actuation Lower. 1 - Indicates the automatic actuation. Drives the SCV I - (lower) output after the feed rolls are engaged in the forward direction...XXXX ...XXX1 0 - Disables Automatic Actuation Lower...XXXX ...XXX0 |
|
|
OUCC020,0001EC1 -19-17OCT05-2/3
|
| ARC - Armrest Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 109 |
Input Calibration |
SCV II Auto Output Mode Time-Out Used to calibrate the time-out for automatic output mode.NOTE: For detailed calibration procedure, see "Address ARC 109 Calibration - SCV II Auto Output Mode Time-Out" in this section. |
| 110 |
Input Calibration |
Automatic Actuation Lower Delay Used to calibrate the delay between feed rolls turning forward and driving the SCV I - output.NOTE: For detailed calibration procedure, see "Address ARC 110 Calibration - Automatic Actuation Lower Delay" in this section. |
| 111 |
Input Calibration |
Automatic Spout Tilt Up Time-Out Used to calibrate the time-out for automatic spout tilt up.NOTE: For detailed calibration procedure, see "Address ARC 111 Calibration - Automatic Spout Tilt Up Time-Out" in this section. |
| 112 |
Input Calibration |
Automatic Spout Rotate Time-Out Used to calibrate the time-out for automatic spout rotate.NOTE: For detailed calibration procedure, see "Address ARC 112 Calibration - Automatic Spout Rotate Time-Out" in this section. |
| 113 |
Input Calibration |
Wagon Dump Automatic Output Mode Time-Out Used to calibrate the time-out for automatic output mode.NOTE: For detailed calibration procedure, see "Address ARC 113 Calibration - Wagon Dump Automatic Output Mode Time-Out" in this section. |
| 119 |
Interactive Calibration |
Row Guidance Potentiometer Calibration Used to calibrate the row guidance potentiometer. |
| 198 |
Display - Operator |
Cutterhead Operating Time |
| 199 |
Display - Operator |
Machine Operating Time |
|
|
OUCC020,0001EC1 -19-17OCT05-3/3
|
|