| SIG - Metal Detector Control Unit Diagnostic Trouble Codes |
| Control Unit |
SPN |
FMI |
Pri. |
Indicator Light |
Description |
Effect |
| SIG |
158 |
00 |
2 |
|
Battery Voltage High. |
Control Unit shutdown, Control Unit functions not available. |
| SIG |
158 |
01 |
2 |
|
Battery Voltage Low. |
Control Unit shutdown, Control Unit functions not available. |
| SIG |
628 |
12 |
2 |
|
Program Memory Failure. |
Control unit functions not available. |
| SIG |
630 |
12 |
|
|
No Factory / Dealer Settings. |
Inital calibration cannot be called back with the reset switch. |
| SIG |
1563 |
12 |
2 |
|
Incompatible Control Unit. |
No control unit function is available. |
| SIG |
300500 |
05 |
3 |
Stationary knife |
Sound Sending Unit A Disconnected. |
Stationary knife adjust function can be performed with one sound sending unit only, not allowed with 2 sound sending units broken. |
| SIG |
300500 |
14 |
3 |
Stationary knife |
Sound Sending Unit A Failed. |
Stationary knife adjust function can be performed with one sound sending unit only. |
| SIG |
300501 |
05 |
3 |
Stationary knife |
Sound Sending Unit B Disconnected. |
Stationary knife adjust function can be performed with one sound sending unit only, not allowed with 2 sound sending units broken. |
| SIG |
300501 |
14 |
3 |
Stationary knife |
Sound Sending Unit B Failed. |
Stationary knife adjust function can be performed with one sound sending unit only. |
| SIG |
300502 |
00 |
2 |
Metal detector |
Feedroll Noise High. |
|
| SIG |
300502 |
05 |
2 |
Metal detector |
Metal Detector Sensor Open Coil. |
|
| SIG |
300502 |
14 |
2 |
Metal detector |
Metal Detector Sensor Disconnected. |
|
| SIG |
300503 |
05 |
2 |
|
Feedrolls Engaged Open Circuit. |
|
| SIG |
300507 |
11 |
2 |
|
Internal High Side Drive Failure / Stop Pawl Disconnected OR Open. |
Control unit error, no stop pawl function, stop pawl connection error. |