SIG - Metal Detector Control Unit Diagnostic Trouble Codes

SIG - Metal Detector Control Unit Diagnostic Trouble Codes
Control Unit SPN FMI Pri. Indicator Light Description Effect
SIG 158 00 2   Battery Voltage High. Control Unit shutdown, Control Unit functions not available.
SIG 158 01 2   Battery Voltage Low. Control Unit shutdown, Control Unit functions not available.
SIG 628 12 2   Program Memory Failure. Control unit functions not available.
SIG 630 12     No Factory / Dealer Settings. Inital calibration cannot be called back with the reset switch.
SIG 1563 12 2   Incompatible Control Unit. No control unit function is available.
SIG 300500 05 3 Stationary knife Sound Sending Unit A Disconnected. Stationary knife adjust function can be performed with one sound sending unit only, not allowed with 2 sound sending units broken.
SIG 300500 14 3 Stationary knife Sound Sending Unit A Failed. Stationary knife adjust function can be performed with one sound sending unit only.
SIG 300501 05 3 Stationary knife Sound Sending Unit B Disconnected. Stationary knife adjust function can be performed with one sound sending unit only, not allowed with 2 sound sending units broken.
SIG 300501 14 3 Stationary knife Sound Sending Unit B Failed. Stationary knife adjust function can be performed with one sound sending unit only.
SIG 300502 00 2 Metal detector Feedroll Noise High.  
SIG 300502 05 2 Metal detector Metal Detector Sensor Open Coil.  
SIG 300502 14 2 Metal detector Metal Detector Sensor Disconnected.  
SIG 300503 05 2   Feedrolls Engaged Open Circuit.  
SIG 300507 11 2   Internal High Side Drive Failure / Stop Pawl Disconnected OR Open. Control unit error, no stop pawl function, stop pawl connection error.

 

OUZXMAG,0001D43 -19-26AUG04-1/1