NOTE:
The condition causing the error must be corrected before the calibration can be continued.
If any errors occur during the calibration procedures, service codes will be displayed on the triple display tachometer.
-
ER01 Feederhouse calibration must be done before header calibration procedure
-
ER02 No header connected or invalid header type
-
ER03 No corn head connected during deck plate calibration
-
ER21 Lateral tilt angle sensor voltage less than 0.5V
-
ER22 Lateral tilt angle sensor voltage greater than 4.5V
-
ER23 Lateral tilt angle sensor voltage noisy or changing in an incorrect direction
-
ER24 Lateral tilt angle voltage range less than 2.0V
-
ER25 Lateral tilt angle sensor "left" voltage greater than 2.5V
-
ER26 Lateral tilt angle sensor "right" voltage less than 2.5V
-
ER27 Lateral tilt angle sensor center voltage is not within 0.75V of mid-range
-
ER39 Lift cylinder pressure sensor voltage less than 1.0 V
-
ER41 Deck plate position sensor voltage less than 0.5V
-
ER42 Deck plate position sensor voltage greater than 4.5V
-
ER43 Deck plate position sensor voltage noisy or changing in an incorrect direction
-
ER44 Deck plate position sensor voltage range less than 2.0V
-
ER45 Deck plate position sensor "closed" voltage greater than 2.5V
-
ER46 Deck plate position sensor "opened" voltage less than 2.5V
-
ER51 Header height resume sensor voltage less than 0.5V
-
ER52 Header height resume sensor voltage greater than 4.5V
|
-
ER53 Header height resume sensor voltage noisy or changing in an incorrect direction
-
ER54 Header height resume sensor voltage range less than 2.0V
-
ER55 Header height resume sensor "lowered" voltage greater than 2.5V
-
ER56 Header height resume sensor "raised" voltage less than 2.5V
-
ER59 Header height resume sensor has excessive hysteresis
-
ER61 Header raise valve deadband not consistent within 80mA
-
ER63 Header raise valve deadband greater than 1200mA
-
ER64 Header raise valve deadband less than 800mA
-
ER66 Header lower valve deadband not consistent within 80mA
-
ER68 Header lower valve deadband greater than 1200mA
-
ER69 Header lower valve deadband less than 800mA
-
ER71 Left height sensor voltage less than 0.5V
-
ER72 Left height position sensor voltage greater than 4.5V
-
ER73 Left height position sensor voltage noisy or changing in an incorrect direction
-
ER74 Left height position sensor voltage range less than 2.0V (1.5V for flex platforms)
-
ER75 Left height position sensor "lowered" voltage greater than 2.5V
-
ER76 Left height position sensor "raised" voltage less than 2.5V
-
ER77 Left and right height sensor not stopping at same feeder house position
-
ER81 Right height sensor voltage less than 0.5V
-
ER82 Right height position sensor voltage greater than 4.5V
-
ER83 Right height position sensor voltage noisy or changing in an incorrect direction
-
ER84 Right height position sensor voltage range less than 2.0V (1.5V for flex platforms)
|