Diagnostic Addresses - C00 Armrest Control Unit

Control Unit Add. Middle Line Lower Line Description Details
Armrest
C00
1 nnnn nn.nn Diagnostic Trouble Codes "none" - indicates there are no Diagnostic Trouble Codes.
"code" - indicates there are Diagnostic Trouble Codes available.
Push ENTER button to view codes. Use UP ARROW and DOWN ARROW to scroll through list of codes.
Armrest
C00
2 _ _ _ _ nnnn BEEP: System The system will show the diagnostic address of any input that changes. Pushing the Enter Button will navigate to that address to display the status of that input.
Armrest
C00
3 _ _ _ _ nnnn BEEP: Analog Inputs The analog inputs are Automatic Header Control Sensitivity, Automatic Header Control Rate, Discharge Beater Speed Sensor, System Battery Voltage, and the Sensor Voltage. The system will show the diagnostic address of any analog input voltage that changes. Pushing the Enter Button will navigate to that address to display the status of that input.
Armrest
C00
4 _ _ _ _ nnnn BEEP: Frequency Inputs The system will show the diagnostic address of Discharge Beater Speed input if it changes. Pushing the Enter Button will navigate to that address to display the status of that input.
Armrest
C00
5 _ _ _ _ nnnn BEEP: Armrest Console and Multifunction Lever Inputs The system will show the diagnostic address of any Armrest Console switch or Multifunction Handle switch that changes. Pushing the Enter Button will navigate to that address to display the status of that input.
Armrest
C00
6 _ _ _ _ nnnn BEEP: Discrete Digital Inputs The discrete digital inputs are the Seat Switch, Neutral Gate Switch, Separator Engage Switch, Header Engage Switch, Key Switch RUN Position, and Key Switch START Position. The system will show the diagnostic address of any discrete digital input that changes. Pushing the Enter Button will navigate to that address to display the status of that input.
Armrest
C00
10 _ _ _ _ nn.nn DISPLAY: System Voltage Analog voltage shown in Volts DC
Armrest
C00
13 _ _ _ _ _n.nn DISPLAY: +5 Volt supply voltage for Automatic Header Control Sensitivity Adjust, Automatic Header Control Rate Adjust and Automatic Header Control Height Encoder Analog voltage shown in Volts DC

 

AG,OUZXMAY,288 -19-21NOV99-1/2


Control Unit Add. Middle Line Lower Line Description Details
Armrest
C00
15 _ _ _ _ nn.nn DISPLAY: Automatic Header Control Sensitivity Adjust Analog voltage shown in Volts DC
Armrest
C00
16 _ _ _ _ nn.nn DISPLAY: Automatic Header Control Rate Adjust Analog voltage shown in Volts DC

 