| Control Unit |
Add. |
Middle Line |
Lower Line |
Description |
Details |
Armrest C00 |
46 |
_ _ _ _ |
1xxx |
DISPLAY: Road / Field Button status |
1 = switch pushed 0 = switch released 3 = undefined input |
Armrest C00 |
50 |
_ _ _ _ |
_ _ 1x |
DISPLAY: Header Engage Switch input |
1 = switch on 0 = switch off |
Armrest C00 |
50 |
_ _ _ _ |
_ _ x1 |
DISPLAY: Separator Engage Switch input |
1 = switch on 0 = switch off |
Armrest C00 |
51 |
_ _ _ _ |
1xxx |
DISPLAY: Key Switch RUN Position input |
1 = key switch in RUN or START position 0 = key switch in OFF or ACC Position |
Armrest C00 |
51 |
_ _ _ _ |
x1xx |
DISPLAY: Key Switch START Position input |
1 = key switch in START position 0 = key switch in OFF, ACC or RUN Position |
Armrest C00 |
51 |
_ _ _ _ |
xxx1 |
DISPLAY: Neutral Gate Switch input |
1 = multifunction lever in neutral gate 0 = multifunction lever not in neutral gate |
Armrest C00 |
51 |
_ _ _ _ |
xx1x |
DISPLAY: Seat Switch input |
1 = operator in seat 0 = operator out of seat |
Armrest C00 |
52 |
_ _ _ _ |
_ x1x |
DISPLAY: Height Control Encoder input from signal 1 |
1 = contacts closed 0 = contacts open |
Armrest C00 |
52 |
_ _ _ _ |
_ xx1 |
DISPLAY: Height Control Encoder input from signal 2 |
1 = contacts closed 0 = contacts open |
Armrest C00 |
52 |
_ _ _ _ |
_ 1xx |
DISPLAY: Status of Beater Speed input |
1 = beater speed input open 0 = beater speed input shorted to ground |
Armrest C00 |
53 |
1xxx |
xxxx |
DISPLAY: Status of output to Auger Engage Valve |
1 = output normal 0 = output shorted or open |
Armrest C00 |
53 |
x1xx |
xxxx |
DISPLAY: Status of output to Header Clutch |
1 = output normal 0 = output shorted or open |
Armrest C00 |
53 |
xx1x |
xxxx |
DISPLAY: Status of output to OK to Start relay or Exit Light relay |
1 = output normal 0 = output shorted or open |
Armrest C00 |
53 |
xxx1 |
xxxx |
DISPLAY: Status of output to Fan Speed Increase relay or Fan Speed Decrease relay |
1 = output normal 0 = output shorted or open |
Armrest C00 |
53 |
xxxx |
x1xx |
DISPLAY: Status of output to Concave Clearance Increase relay or Concave Clearance Decrease relay |
1 = output normal 0 = output shorted or open |
Armrest C00 |
53 |
xxxx |
xx1x |
DISPLAY: Status of output to Draper Speed Increase relay or Draper Speed Decrease relay |
1 = output normal 0 = output shorted or open |