Diagnostic Addresses - C00 Armrest Control Unit, con't

Control Unit Add. Middle Line Lower Line Description Details
Armrest
C00
54 1xxx xxxx DISPLAY: Status of output to Auger Fold relay or Auger Unfold relay 1 = output normal
0 = output shorted or open
Armrest
C00
54 xx1x xxxx DISPLAY: status of "out of neutral" output to the Warning Display Panel 1 = output normal
0 = output shorted or open
Armrest
C00
54 xxx1 xxxx DISPLAY: Status of output to Sidehill engage relay or Auger Light relay 1 = output normal
0 = output shorted or open
Armrest
C00
54 xxxx 1xxx DISPLAY: Status of output to Unloading Auger Swing In relay or Unloading Auger Swing Out relay 1 = output normal
0 = output shorted or open
Armrest
C00
54 xxxx x1xx DISPLAY: Status of output to Cylinder Speed Increase relay or Cylinder Speed Decrease relay 1 = output normal
0 = output shorted or open
Armrest
C00
54 xxxx xxx1 DISPLAY: Status of output to Four wheel Drive Engage Valve 1 = output normal
0 = output shorted or open
Armrest
C00
54 xxxx xx1x DISPLAY: Status of output to Separator Engage Valve 1 = output normal
0 = output shorted or open
Armrest
C00
70 _ _ _ _ _ nnn DISPLAY: unloading auger position Shown in percent
Range = 0 - 100.0%
Armrest
C00
71 _ _ _ _ _ nnn DISPLAY: Height Control Encoder position As the encoder is rotated clockwise the number will increase. As the encoder is rotated counter clockwise the number will decrease.
Range = 0 - 255
Armrest
C00
72 _ _ _ _ nnnn DISPLAY: Armrest Hours Time (shown in hours) the Armrest Control Unit has been powered.
Armrest
C00
90 1xxx xxxx DISPLAY: Key Switch status 1 = key switch in START position
0 = key switch in OFF, ACC or RUN Position
Armrest
C00
90 x1xx xxxx DISPLAY: status of unloading auger swing out relay for Start Interlock 1 = output to relay turned off. Interlock will allow engine start.
0 = output to relay turned on. Interlock will not allow engine start.
Armrest
C00
90 xx1x xxxx DISPLAY: status of unloading auger swing in relay for Start Interlock 1 = output to relay turned off. Interlock will allow engine start.
0 = output to relay turned on. Interlock will not allow engine start.
Armrest
C00
90 xxx1 xxxx DISPLAY: status of auger engage for Start Interlock 1 = output to valve turned off. Interlock will allow engine start.
0 = output to valve turned on. Interlock will not allow engine start.

 

AG,OUZXMAY,293 -19-20NOV99-1/1