Diagnostic Addresses - C00 Armrest Control Unit, con't

Control Unit Add. Middle Line Lower Line Description Details
Armrest
C00
92 xxxx 1xxx DISPLAY: Road / field mode for header engage interlock 1 = interlock will allow header to be engaged. Combine is in FIELD mode.
0 = interlock will not allow header to be engaged. Combine is in ROAD mode.
Armrest
C00
93 1xxx xxxx DISPLAY: Auger engage latch interlock 1 = Auger is swung out to more than 50% of full swing. Interlock allows auger to latch engaged.
0 = Auger is swung out to less than 50% of full swing. Interlock prevents auger from latching engaged.
Armrest
C00
93 x1xx xxxx DISPLAY: Auger engage latch interlock 1 = auger is not automatically swinging in. Interlock allows auger to latch engaged.
0 = Auger is automatically swinging in. Interlock prevents auger from latching engaged.
Armrest
C00
93 xx1x xxxx DISPLAY: Quick stop unloading auger engage interlock 1 = interlock will allow unloading auger to be engaged. Quick Stop Button is not pushed.
0 = interlock will not allow unloading auger to be engaged. Quick Stop Button is pushed.
Armrest
C00
93 xxx1 xxxx DISPLAY: Key switch START unloading auger interlock 1 = interlock will allow unloading auger to be engaged. Key Switch is not in START position.
0 = interlock will not allow unloading auger to be engaged. Key Switch is in START position.
Armrest
C00
93 xxxx 1xxx DISPLAY: Road / field mode for unloading auger engage interlock 1 = interlock will allow unloading auger to be engaged. Combine is in FIELD mode.
0 = interlock will not allow unloading auger to be engaged. Combine is in ROAD mode.
Armrest
C00
93 xxxx x1xx DISPLAY: Load condition auger interlock 1 = FET status indicates the auger engage valve and wiring are ok.
0 = auger engage valve or wiring are shorted or open.
Armrest
C00
93 xxxx xx1x DISPLAY: Auger Engage Button input 1 = switch on
0 = switch off
Armrest
C00
93 xxxx xxx1 DISPLAY: Auger engage signal 1 = Auger engage signal sent by controller to auger engage valve.
Armrest
C00
100 _ _ _ _ _ _ nn DISPLAY/MODIFY: Auger swing out time Increase number to lengthen the time the valve is energized during automatic unloading auger swing out. Decrease the number to shorten the time.
Range = 0 - 20
Default = 13

 

AG,OUZXMAY,295 -19-20NOV99-1/1