Diagnostic Addresses - C00 Armrest Control Unit, con't

Control Unit Add. Middle Line Lower Line Description Details
Armrest
C00
101 _ _ _ _ _ _ nn DISPLAY/MODIFY: Auger swing in time Increase number to lengthen the time the valve is energized during automatic unloading auger swing in. Decrease the number to shorten the time.
Range = 0 - 20
Default = 15
Armrest
C00
120 _ _ _ _ xxx1 DISPLAY: status of output to 4 wheel drive indicator 1 = output to indicator turned on
0 = output to indicator turned off
Armrest
C00
120 _ _ _ _ x1xx DISPLAY: status of output to road / field indicator 1 = output to indicator turned on
0 = output to indicator turned off
Armrest
C00
121 _ _ _ _ 1xxx DISPLAY: status of output to unloading auger engaged indicator 1 = output to indicator turned on
0 = output to indicator turned off
Armrest
C00
121 _ _ _ _ x1xx DISPLAY: status of output to hi idle indicator 1 = output to indicator turned on
0 = output to indicator turned off
Armrest
C00
121 _ _ _ _ xx1x DISPLAY: status of output to mid idle indicator 1 = output to indicator turned on
0 = output to indicator turned off
Armrest
C00
121 _ _ _ _ xxx1 DISPLAY: status of output to lo idle indicator 1 = output to indicator turned on
0 = output to indicator turned off
Armrest
C00
122 _ _ _ _ _ _ 1x DISPLAY: status of output to auger light relay 1 = output to relay turned on
0 = output to relay turned off
Armrest
C00
122 _ _ _ _ _ _ x1 DISPLAY: status of output to exit light relays 1 = output to relays turned on
0 = output to relays turned off
Armrest
C00
123 _ _ _ _ 1xxx DISPLAY: status of output to fan speed increase relay 1 = output to relays turned on
0 = output to relays turned off
Armrest
C00
123 _ _ _ _ x1xx DISPLAY: status of output to fan speed decrease relay 1 = output to relays turned on
0 = output to relays turned off
Armrest
C00
123 _ _ _ _ xx1x DISPLAY: status of output to concave increase relay 1 = output to relays turned on
0 = output to relays turned off
Armrest
C00
123 _ _ _ _ xxx1 DISPLAY: status of output to concave decrease relay 1 = output to relays turned on
0 = output to relays turned off
Armrest
C00
124 _ _ _ _ _ 1xx DISPLAY: status of output to cylinder speed change relay 1 = output to relays turned on
0 = output to relays turned off
Armrest
C00
125 _ _ _ _ 1xxx DISPLAY: status of output to auger fold relay 1 = output to relay turned on
0 = output to relay turned off
Armrest
C00
125 _ _ _ _ x1xx DISPLAY: status of output to auger unfold relay 1 = output to relay turned on
0 = output to relay turned off

 

AG,OUZXMAY,296 -19-20NOV99-1/1