| Control Unit |
Add. |
Middle Line |
Lower Line |
Description |
Details |
Armrest C00 |
101 |
_ _ _ _ |
_ _ nn |
DISPLAY/MODIFY: Auger swing in time |
Increase number to lengthen the time the valve is energized during automatic unloading auger swing in. Decrease the number to shorten the time. Range = 0 - 20 Default = 15 |
Armrest C00 |
120 |
_ _ _ _ |
xxx1 |
DISPLAY: status of output to 4 wheel drive indicator |
1 = output to indicator turned on 0 = output to indicator turned off |
Armrest C00 |
120 |
_ _ _ _ |
x1xx |
DISPLAY: status of output to road / field indicator |
1 = output to indicator turned on 0 = output to indicator turned off |
Armrest C00 |
121 |
_ _ _ _ |
1xxx |
DISPLAY: status of output to unloading auger engaged indicator |
1 = output to indicator turned on 0 = output to indicator turned off |
Armrest C00 |
121 |
_ _ _ _ |
x1xx |
DISPLAY: status of output to hi idle indicator |
1 = output to indicator turned on 0 = output to indicator turned off |
Armrest C00 |
121 |
_ _ _ _ |
xx1x |
DISPLAY: status of output to mid idle indicator |
1 = output to indicator turned on 0 = output to indicator turned off |
Armrest C00 |
121 |
_ _ _ _ |
xxx1 |
DISPLAY: status of output to lo idle indicator |
1 = output to indicator turned on 0 = output to indicator turned off |
Armrest C00 |
122 |
_ _ _ _ |
_ _ 1x |
DISPLAY: status of output to auger light relay |
1 = output to relay turned on 0 = output to relay turned off |
Armrest C00 |
122 |
_ _ _ _ |
_ _ x1 |
DISPLAY: status of output to exit light relays |
1 = output to relays turned on 0 = output to relays turned off |
Armrest C00 |
123 |
_ _ _ _ |
1xxx |
DISPLAY: status of output to fan speed increase relay |
1 = output to relays turned on 0 = output to relays turned off |
Armrest C00 |
123 |
_ _ _ _ |
x1xx |
DISPLAY: status of output to fan speed decrease relay |
1 = output to relays turned on 0 = output to relays turned off |
Armrest C00 |
123 |
_ _ _ _ |
xx1x |
DISPLAY: status of output to concave increase relay |
1 = output to relays turned on 0 = output to relays turned off |
Armrest C00 |
123 |
_ _ _ _ |
xxx1 |
DISPLAY: status of output to concave decrease relay |
1 = output to relays turned on 0 = output to relays turned off |
Armrest C00 |
124 |
_ _ _ _ |
_ 1xx |
DISPLAY: status of output to cylinder speed change relay |
1 = output to relays turned on 0 = output to relays turned off |
Armrest C00 |
125 |
_ _ _ _ |
1xxx |
DISPLAY: status of output to auger fold relay |
1 = output to relay turned on 0 = output to relay turned off |
Armrest C00 |
125 |
_ _ _ _ |
x1xx |
DISPLAY: status of output to auger unfold relay |
1 = output to relay turned on 0 = output to relay turned off |