| Control Unit |
Add. |
Middle Line |
Lower Line |
Description |
Details |
Tailings E00 |
1 |
nnnn |
nn.nn |
Diagnostic Trouble Codes |
"none" - indicates there are no Diagnostic Trouble Codes. "code" - indicates there are Diagnostic Trouble Codes available. Push ENTER button to view codes. Use UP ARROW and DOWN ARROW to scroll through list of codes. |
Tailings E00 |
2 |
_ _ _ _ |
nnnn |
BEEP: System |
The system will show the diagnostic address of any input that changes. Pushing the Enter Button will navigate to that address to display the status of that input. |
Tailings E00 |
5 |
_ _ _ _ |
nnnn |
BEEP: Discrete Digital beep mode |
The system will show the diagnostic address of any discrete digital input that changes. Pushing the Enter Button will navigate to that address to display the status of that input. |
Tailings E00 |
30 |
_ _ _ _ |
1xxx |
DISPLAY: Slave Sensor detector #4 (furthest from elevator chain) |
1 = detecting light 0 = not detecting light |
Tailings E00 |
30 |
_ _ _ _ |
x1xx |
DISPLAY: Slave Sensor detector #3 |
1 = detecting light 0 = not detecting light |
Tailings E00 |
30 |
_ _ _ _ |
xx1x |
DISPLAY: Slave Sensor detector #2 |
1 = detecting light 0 = not detecting light |
Tailings E00 |
30 |
_ _ _ _ |
xxx1 |
DISPLAY: Slave Sensor detector #1 (closest to elevator chain) |
1 = detecting light 0 = not detecting light |
Tailings E00 |
31 |
_ _ _ _ |
1xxx |
DISPLAY: Master Sensor detector #4 (furthest from elevator chain) |
1 = detecting light 0 = not detecting light |
Tailings E00 |
31 |
_ _ _ _ |
x1xx |
DISPLAY: Master Sensor detector #3 |
1 = detecting light 0 = not detecting light |
Tailings E00 |
31 |
_ _ _ _ |
xx1x |
DISPLAY: Master Sensor detector #2 |
1 = detecting light 0 = not detecting light |
Tailings E00 |
31 |
_ _ _ _ |
xxx1 |
DISPLAY: Master Sensor detector #1 (closest to elevator chain) |
1 = detecting light 0 = not detecting light |
Tailings E00 |
51 |
_ _ _ _ |
xxx1 |
DISPLAY: status of header engaged CAN Bus message |
1 = header engaged 0 = header disengaged |
Tailings E00 |
52 |
_ _ _ _ |
xxx1 |
DISPLAY: status of separator engaged CAN Bus message |
1 = separator engaged 0 = separator disengaged |
Tailings E00 |
53 |
_ _ _ _ |
xxx1 |
DISPLAY: status of seed size CAN Bus message |
1 = small seed 2 = medium seed 3 = large seed |
Tailings E00 |
70 |
_ _ _ _ |
_ _ nn |
DISPLAY: Tailings percent |
Percent of full scale display shown on Cornerpost Display Unit 2 |
Tailings E00 |
71 |
_ _ _ _ |
xxx1 |
DISPLAY: Calibration flag |
1 = calibration in progress |