Diagnostic Addresses - E00 Tailings Master Sensor, con't

Control Unit Add. Middle Line Lower Line Description Details
Tailings
E00
100 _ _ _ _ _ nnn DISPLAY/MODIFY: Small seed scaling value Increase number to show more bars.
Range = 0 to 250
Default = 100
Tailings
E00
101 _ _ _ _ _ nnn DISPLAY/MODIFY: Medium seed scaling value Increase number to show more bars.
Range = 0 to 250
Default = 100
Tailings
E00
102 _ _ _ _ _ nnn DISPLAY/MODIFY: Large seed scaling value Increase number to show more bars.
Range = 0 to 250
Default = 100
Tailings
E00
120 _ _ _ _ _ n.nn DISPLAY: Slave sensor calibration value Range = 0.1 - 0.45
Tailings
E00
121 _ _ _ _ _ n.nn DISPLAY: Master sensor calibration value Range = 0.1 - 0.45
Tailings
E00
227 _ _ nn nnnn DISPLAY: Part number of the boot block program  
Tailings
E00
228 _ _ _ _ nnnn DISPLAY: Version number of the boot block program  
Tailings
E00
233 _ _ nn nnnn DISPLAY: Base program part number  
Tailings
E00
234 _ _ _ _ nnnn DISPLAY: Base program version number  
Tailings
E00
235 _ _ nn nnnn DISPLAY: Device part number  
Tailings
E00
236 _ _ _ _ nnnn DISPLAY: Device serial number  
Tailings
E00
247 _ _ _ _ _ _ nn DISPLAY: Machine Model Number 12 - 9650CTS

 

AG,OUZXMAY,308 -19-20NOV99-1/1