Diagnostic Addresses - E01 Header Control Unit

Control Unit Add. Middle Line Lower Line Description Details
Header
E01
1 nnnn nn.nn Diagnostic Trouble Codes "none" - indicates there are no Diagnostic Trouble Codes.
"code" - indicates there are Diagnostic Trouble Codes available.
Push ENTER button to view codes. Use UP ARROW and DOWN ARROW to scroll through list of codes.
Header
E01
2 _ _ _ _ nnnn BEEP: System The system will show the diagnostic address of any input that changes. Pushing the Enter Button will navigate to that address to display the status of that input.
Header
E01
10 _ _ _ _ _ nn.n DISPLAY: EMIP Power (CC #21) to Header Control Unit at X206, Pin J1. This is used to power the logic circuits of the control unit. Analog voltage shown in Volts DC. Battery Voltage
Header
E01
11 _ _ _ _ nn.nn DISPLAY: CAN Bus Low › analog voltage Analog voltage shown in Volts DC
Header
E01
12 _ _ _ _ nn.nn DISPLAY: CAN Bus High › analog voltage Analog voltage shown in Volts DC
Header
E01
13 _ _ _ _ _ nn.n DISPLAY: Engine Running Power (CC #15) to Header Control Unit at X206, Pin K3. This is used to power the valve driver circuits of the control unit. Analog voltage shown in Volts DC. Battery Voltage. Engine must be running.
Header
E01
14 _ _ _ _ _nn.n DISPLAY: Engine Running Power (CC #15) to Header Control Unit at X206, Pin E3. This is used to power the reel valve driver circuits of the control unit. Analog voltage shown in Volts DC. Battery voltage. Engine must be running.
Header
E01
15 _ _ _ _ _ n.nn DISPLAY: Sensor supply voltage (Circuit Code 481) from the Header Control Unit. This is used to power the Height Resume and Header Height Sensors Analog voltage shown in Volts DC. 4.8 - 5.2 V is normal.
Header
E01
16 _ _ _ _ _ n.nn DISPLAY: Sensor supply voltage (Circuit Code 471) from the Header Control Unit. This is used to power the Automatic Header Control Angle Sensor Analog voltage shown in Volts DC. 4.8 - 5.2 V is normal.
Header
E01
17 _ _ _ _ nn.nn DISPLAY: Feeder House l.h. (return to cut) Sensor voltage Analog voltage shown in Volts DC
Header
E01
18 _ _ _ _ nn.nn DISPLAY: Feeder House Angle Sensor voltage Analog voltage shown in Volts DC
Header
E01
19 _ _ _ _ nn.nn DISPLAY: Lift cylinder pressure sensor voltage Analog voltage shown in Volts DC

 

AG,OUZXMAY,309 -19-18FEB00-1/2


Control Unit Add. Middle Line Lower Line Description Details
Header
E01
20 _ _ _ _ xx.xx DISPLAY: Reel fore/aft position sensor voltage Analog voltage shown in Volts DC
Header
E01
21 _ _ _ _ xx.xx DISPLAY: Reel up/down position sensor voltage Analog voltage shown in Volts DC

 

AG,OUZXMAY,309 -19-18FEB00-2/2