| Control Unit |
Add. |
Middle Line |
Lower Line |
Description |
Details |
Header E01 |
62 |
_ _ _ _ |
xx1x |
DISPLAY: Resume 2 Button - CAN Message from Armrest Control Unit |
1 = CAN Bus message received that switch is pushed 0 = no message received or message received that switch is released |
Header E01 |
62 |
_ _ _ _ |
xxx1 |
DISPLAY: Resume 1 Button - CAN Message from Armrest Control Unit |
1 = CAN Bus message received that switch is pushed 0 = no message received or message received that switch is released |
Header E01 |
63 |
_ _ _ _ |
xxx1 |
DISPLAY: Dump Valve Request - CAN Message from Armrest Control Unit |
1 = CAN Bus message received that dump valve activation is requested 0 = no message received or message received that dump valve request is cancelled. |
Header E01 |
63 |
_ _ _ _ |
1xxx |
DISPLAY: Reel Speed Increase Button - CAN Message from Armrest Control Unit |
1 = CAN Bus message received that switch is pushed 0 = no message received or message received that switch is released |
Header E01 |
63 |
_ _ _ _ |
x1xx |
DISPLAY: Reel Speed Decrease Button - CAN Message from Armrest Control Unit |
1 = CAN Bus message received that switch is pushed 0 = no message received or message received that switch is released |
Header E01 |
63 |
_ _ _ _ |
xx1x |
DISPLAY: Road/Field Status - CAN Message from Armrest Control Unit |
1 = CAN Bus message received that combine is in road mode 0 = CAN Bus message received that combine is in field mode |
Header E01 |
64 |
_ _ _ _ |
_ nnn |
DISPLAY: Automatic Header Control Height Encoder value |
Clockwise rotation increases value. Counterclockwise rotation decreases value. Range = 0 - 255 |
Header E01 |
65 |
_ _ _ _ |
_ nnn |
DISPLAY: Automatic Header Control Sensitivity Adjust setting |
Clockwise rotation increases value. Counterclockwise rotation decreases value. Range = 0 - 100 |
Header E01 |
66 |
_ _ _ _ |
_ nnn |
DISPLAY: Automatic Header Control Rate Adjust setting |
Clockwise rotation increases value. Counterclockwise rotation decreases value Range = 0 - 100 |
Header E01 |
70 |
_ _ _ _ |
1xxx |
DISPLAY: Machine configuration - header lift valve type |
1 = Proportional Valve 0 = Poppet Valve |
Header E01 |
70 |
_ _ _ _ |
x1xx |
DISPLAY: Machine configuration - reel lift valve type |
1 = separate reel lift and reel lower valves 0 = single height valve |
Header E01 |
70 |
_ _ _ _ |
xxx1 |
DISPLAY: Machine configuration - Automatic Header Control |
1 = installed 0 = not installed |