Diagnostic Addresses - E01 Header Control Unit, con't

Control Unit Add. Middle Line Lower Line Description Details
Header
E01
62 _ _ _ _ xx1x DISPLAY: Resume 2 Button - CAN Message from Armrest Control Unit 1 = CAN Bus message received that switch is pushed
0 = no message received or message received that switch is released
Header
E01
62 _ _ _ _ xxx1 DISPLAY: Resume 1 Button - CAN Message from Armrest Control Unit 1 = CAN Bus message received that switch is pushed
0 = no message received or message received that switch is released
Header
E01
63 _ _ _ _ xxx1 DISPLAY: Dump Valve Request - CAN Message from Armrest Control Unit 1 = CAN Bus message received that dump valve activation is requested
0 = no message received or message received that dump valve request is cancelled.
Header
E01
63 _ _ _ _ 1xxx DISPLAY: Reel Speed Increase Button - CAN Message from Armrest Control Unit 1 = CAN Bus message received that switch is pushed
0 = no message received or message received that switch is released
Header
E01
63 _ _ _ _ x1xx DISPLAY: Reel Speed Decrease Button - CAN Message from Armrest Control Unit 1 = CAN Bus message received that switch is pushed
0 = no message received or message received that switch is released
Header
E01
63 _ _ _ _ xx1x DISPLAY: Road/Field Status - CAN Message from Armrest Control Unit 1 = CAN Bus message received that combine is in road mode
0 = CAN Bus message received that combine is in field mode
Header
E01
64 _ _ _ _ _ nnn DISPLAY: Automatic Header Control Height Encoder value Clockwise rotation increases value. Counterclockwise rotation decreases value.
Range = 0 - 255
Header
E01
65 _ _ _ _ _ nnn DISPLAY: Automatic Header Control Sensitivity Adjust setting Clockwise rotation increases value. Counterclockwise rotation decreases value.
Range = 0 - 100
Header
E01
66 _ _ _ _ _ nnn DISPLAY: Automatic Header Control Rate Adjust setting Clockwise rotation increases value. Counterclockwise rotation decreases value
Range = 0 - 100
Header
E01
70 _ _ _ _ 1xxx DISPLAY: Machine configuration - header lift valve type 1 = Proportional Valve
0 = Poppet Valve
Header
E01
70 _ _ _ _ x1xx DISPLAY: Machine configuration - reel lift valve type 1 = separate reel lift and reel lower valves
0 = single height valve
Header
E01
70 _ _ _ _ xxx1 DISPLAY: Machine configuration - Automatic Header Control 1 = installed
0 = not installed

 

AG,OUZXMAY,312 -19-12SEP00-1/1