| Control Unit |
Add. |
Middle Line |
Lower Line |
Description |
Details |
Header E01 |
103 |
FCAL |
_ _ _ _ |
CALIBRATION: Float Interactive Calibration Mode |
|
Header E01 |
104 |
CCAL |
_ _ _ _ |
CALIBRATION: Adjustable Deck Plate Interactive Calibration Mode |
|
Header E01 |
105 |
ACAL |
xxxx |
DISPLAY: Header height, Area counter |
0 = off 1 = on |
Header E01 |
110 |
_ _ _ _ |
_ n.nn |
DISPLAY/MODIFY: Manual header raise time to disable auto Lateral Tilt |
Shown in seconds. Range = 0.50 -2.50 Default = 1.50 |
Header E01 |
111 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Dead Band for Automatic Header Control algorithm |
Range = 50 - 250 Default = 150 |
Header E01 |
115 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Gain for Automatic Header Control algorithm |
Increase number to slow response of Automatic Header Control to changes Range = 2-8 Default = 6 |
Header E01 |
116 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Header Height Resume display range |
Range =0 - 99.9 Default = set by header type |
Header E01 |
117 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Header Height Control display range |
Range =0 - 99.9 Default = set by header type |
Header E01 |
125 |
_ _ _ _ |
nnnn |
DISPLAY/MODIFY: Header Width |
Range =0 - 9999 Default = set by header type |
Header E01 |
130 |
_ _ _ _ |
_ nnn |
DISPLAY: Height valve command |
000 = Valve off 150 = Raise Slow 199 = Raise Fast 250 = Lower Slow 299 = Lower Fast |
Header E01 |
131 |
_ 1xx |
xxxx |
DISPLAY: Tilt Left Valve command |
1 = output to valve turned on 0 = valve off |
Header E01 |
131 |
_ x1x |
xxxx |
DISPLAY: Tilt Right Valve command |
1 = output to valve turned on 0 = valve off |
Header E01 |
131 |
_ xx1 |
xxxx |
DISPLAY: Dump Valve command |
1 = output to valve turned on 0 = valve off |