Diagnostic Addresses - E01 Header Control Unit, con't

Control Unit Add. Middle Line Lower Line Description Details
Header
E01
131 _ xxx 1xxx DISPLAY: Reel Fore Valve command 1 = output to valve turned on
0 = valve off
Header
E01
131 _ xxx x1xx DISPLAY: Reel Aft Valve command 1 = output to valve turned on
0 = valve off
Header
E01
131 _ xxx xx1x DISPLAY: Reel Raise Valve command (used with Dump Valve Command) 1 = output to valve turned on
0 = valve off
Header
E01
131 _ xxx xxx1 DISPLAY: Reel Lower Valve command 1 = output to valve turned on
0 = valve off
Header
E01
132 _ _ _ _ _ _ 1x DISPLAY: Accumulator Shutoff Valve command 1 = output to valve turned on
0 = valve off
Header
E01
132 _ _ _ _ _ _ x1 DISPLAY: Header Drop Rate Valve command 1 = output to valve turned on
0 = valve off
Header
E01
133 _ _ _ _ _ nnn DISPLAY: Reel speed motor command 000 = motor off
125 = increasing slow
225 = decreasing slow
Header
E01
140 _ _ _ _ x1xx DISPLAY: Deck Plate Spacing Sensor 1 = Automatic Header Control System recognizes sensors due to input from sensors greater than 0.5VDC
0 = Automatic Header Control System does not recognize sensors due to input from sensors less than 0.5VDC
Header
E01
140 _ _ _ _ xx1x DISPLAY: Center Header Height Sensor 1 = Automatic Header Control System recognizes sensors due to input from sensors greater than 0.5VDC
0 = Automatic Header Control System does not recognize sensors due to input from sensors less than 0.5VDC
Header
E01
140 _ _ _ _ xxx1 DISPLAY: Left and Right Contacting Header Height Sensors 1 = Automatic Header Control System recognizes sensors due to input from sensors greater than 0.5VDC
0 = Automatic Header Control System does not recognize sensors due to input from sensors less than 0.5VDC

 

AG,OUZXMAY,315 -19-18FEB00-1/1