| Control Unit |
Add. |
Middle Line |
Lower Line |
Description |
Details |
Header E01 |
131 |
_ xxx |
1xxx |
DISPLAY: Reel Fore Valve command |
1 = output to valve turned on 0 = valve off |
Header E01 |
131 |
_ xxx |
x1xx |
DISPLAY: Reel Aft Valve command |
1 = output to valve turned on 0 = valve off |
Header E01 |
131 |
_ xxx |
xx1x |
DISPLAY: Reel Raise Valve command (used with Dump Valve Command) |
1 = output to valve turned on 0 = valve off |
Header E01 |
131 |
_ xxx |
xxx1 |
DISPLAY: Reel Lower Valve command |
1 = output to valve turned on 0 = valve off |
Header E01 |
132 |
_ _ _ _ |
_ _ 1x |
DISPLAY: Accumulator Shutoff Valve command |
1 = output to valve turned on 0 = valve off |
Header E01 |
132 |
_ _ _ _ |
_ _ x1 |
DISPLAY: Header Drop Rate Valve command |
1 = output to valve turned on 0 = valve off |
Header E01 |
133 |
_ _ _ _ |
_ nnn |
DISPLAY: Reel speed motor command |
000 = motor off 125 = increasing slow 225 = decreasing slow |
Header E01 |
140 |
_ _ _ _ |
x1xx |
DISPLAY: Deck Plate Spacing Sensor |
1 = Automatic Header Control System recognizes sensors due to input from sensors greater than 0.5VDC 0 = Automatic Header Control System does not recognize sensors due to input from sensors less than 0.5VDC |
Header E01 |
140 |
_ _ _ _ |
xx1x |
DISPLAY: Center Header Height Sensor |
1 = Automatic Header Control System recognizes sensors due to input from sensors greater than 0.5VDC 0 = Automatic Header Control System does not recognize sensors due to input from sensors less than 0.5VDC |
Header E01 |
140 |
_ _ _ _ |
xxx1 |
DISPLAY: Left and Right Contacting Header Height Sensors |
1 = Automatic Header Control System recognizes sensors due to input from sensors greater than 0.5VDC 0 = Automatic Header Control System does not recognize sensors due to input from sensors less than 0.5VDC |