| Control Unit |
Add. |
Middle Line |
Lower Line |
Description |
Details |
Header E01 |
142 |
_ _ _ _ |
_ xxn |
DISPLAY: Reel Raise/Lower operating mode |
0 = off 1 = Manual Enable 4 = Manual Reel Raise 5 = Manual Reel Lower 6 = Reel Resume - Header Activation Button 1 7 = Reel Resume - Header Activation Button 2 8 = Reel Resume - Header Activation Button 3 |
Header E01 |
142 |
_ _ _ _ |
_ nxx |
DISPLAY: Reel Speed operating mode |
0 = Dial-A-Speed Header Control Off 1 = Manual Enable 2 = Manual Speed Increase 3 = Manual Speed Decrease |
Header E01 |
143 |
_ _ _ n |
nnnn |
DISPLAY: Failure overriding modes. This number is the sum of all failure modes existing at once. |
0 = Normal 1 = Shut off raise/lower valves due to valve driver problems 2 = Shut off tilt valves 4 = No Header Height Resume 8 = No Height Sensing, Height Float or Height Resume 16 = No Height Sensing 32 = No Height Float 64 = No Automatic Header Control 128 = No Automatic Header Control with Noncontacting (ultrasonic) sensors 256 = No Reel Resume Raise/Lower for Header Activation Button 1 512 = No Reel Resume Fore/Aft for Header Activation Button 1 1024 = No Reel Resume Raise/Lower for Header Activation Button 2 2048 = No Reel Resume Fore/Aft for Header Activation Button 2 4096 = No Reel Resume Raise/Lower for Header Activation Button 3 8192 = No Reel Resume Fore/Aft for Header Activation Button 3 |
Header E01 |
144 |
_ _ _ _ |
_ nnn |
DISPLAY: Feederhouse position command |
Command by controller Range = 0 - 127 |
Header E01 |
145 |
_ _ _ _ |
_ nnn |
DISPLAY: Position set point |
Set by rotating Height Control Encoder Range = 0 - 127 |
Header E01 |
146 |
_ _ _ _ |
_ nnn |
DISPLAY: Feederhouse position |
Input from Height Resume Sensor Range = 0 - 127 |