E00 Tailings Control Unit

Diagnostic Addresses - E00 Tailings Control Unit

Control Unit Add. Line 2 Line 3 Description Details
Tailings E00 1 nnnn nn.nn Diagnostic Trouble Codes "none" - indicates there are no Diagnostic Trouble Codes.
"code" - indicates there are Diagnostic Trouble Codes available.
Push ENTER button to view codes. Use ARROW-UP and ARROW-DOWN to scroll through list of codes.
Tailings E00 2 _ _ _ _ nnnn BEEP: System The system will show the diagnostic address of any input that changes. Pushing the Enter Button will navigate to that address to display the status of that input.
Tailings E00 3 _ _ _ _ nnnn BEEP: Discrete digital beep mode The system will show the diagnostic address of any discrete digital input that changes. Pushing the Enter Button will navigate to that address to display the status of that input.
Tailings E00 30 _ _ _ _ 1xxx DISPLAY: Slave Sensor detector #4 (furthest from elevator chain) 1 = detecting light
0 = not detecting light
Tailings E00 30 _ _ _ _ x1xx DISPLAY: Slave Sensor detector #3 1 = detecting light
0 = not detecting light
Tailings E00 30 _ _ _ _ xx1x DISPLAY: Slave Sensor detector #2 1 = detecting light
0 = not detecting light
Tailings E00 30 _ _ _ _ xxx1 DISPLAY: Slave Sensor detector #1 (closest to elevator chain) 1 = detecting light
0 = not detecting light
Tailings E00 31 _ _ _ _ 1xxx DISPLAY: Master Sensor detector #4 (furthest from elevator chain) 1 = detecting light
0 = not detecting light
Tailings E00 31 _ _ _ _ x1xx DISPLAY: Master Sensor detector #3 1 = detecting light
0 = not detecting light
Tailings E00 31 _ _ _ _ xx1x DISPLAY: Master Sensor detector #2 1 = detecting light
0 = not detecting light
Tailings E00 31 _ _ _ _ xxx1 DISPLAY: Master Sensor detector #1 (closest to elevator chain) 1 = detecting light
0 = not detecting light
Tailings E00 50 _ _ _ _ _ _ _ 1 DISPLAY: Status of header engaged CAN Bus message 1 = header engaged
0 = header disengaged
Tailings E00 51 _ _ _ _ _ _ _ 1 DISPLAY: Status of separator engaged CAN Bus message 1 = separator engaged
0 = separator disengaged
Tailings E00 52 _ _ _ _ _ _ _ 1 DISPLAY: Status of seed size CAN Bus message 1 = small seed
2 = medium seed
3 = large seed
Tailings E00 70 _ _ _ _ _ nnn DISPLAY: Tailings percentage Percentage of full scale display shown on Cornerpost Display Unit 2
Tailings E00 71 _ _ _ _ _ _ _ 1 DISPLAY: Calibration flag 1 = calibration in progress

 

OUZXMAG,00018AD -19-10OCT02-1/2


Control Unit Add. Line 2 Line 3 Description Details
Tailings E00 100 _ _ _ _ _ nnn DISPLAY/MODIFY: Small seed scaling value Increase number to show more bars.
Range = 0 to 250
Default = 100
Tailings E00 101 _ _ _ _ _ nnn DISPLAY/MODIFY: Medium seed scaling value Increase number to show more bars.
Range = 0 to 250
Default = 100
Tailings E00 102 _ _ _ _ _ nnn DISPLAY/MODIFY: Large seed scaling value Increase number to show more bars.
Range = 0 to 250
Default = 100
Tailings E00 120 _ _ _ _ _ n.nn DISPLAY: Slave sensor calibration value Range = 0.10 - 0.45
Tailings E00 121 _ _ _ _ _ n.nn DISPLAY: Master sensor calibration value Range = 0.10 - 0.45
Tailings E00 227 _ _ nn nnnn DISPLAY: Part number of the boot block program  
Tailings E00 228 _ _ _ _ nnnn DISPLAY: Version number of the boot block program  
Tailings E00 233 _ _ nn nnnn DISPLAY: Base program part number  
Tailings E00 234 _ _ _ _ nnnn DISPLAY: Base program version number  
Tailings E00 235 _ _ nn nnnn DISPLAY: Device part number  
Tailings E00 236 _ _ _ _ nnnn DISPLAY: Device serial number  
Tailings E00 247 _ _ _ _ _ _ nn DISPLAY: Machine Model Number 14 = 9640, 9660, 9680
16 = 9540, 9560, 9580

 

OUZXMAG,00018AD -19-10OCT02-2/2