| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
1 |
nnnn |
nn.nn |
Diagnostic Trouble Codes |
"none" - indicates there are no Diagnostic Trouble Codes. "code" - indicates there are Diagnostic Trouble Codes available. Push ENTER button to view codes. Use ARROW-UP and ARROW-DOWN to scroll through list of codes. |
| Header E01 |
2 |
_ _ _ _ |
nnnn |
BEEP: System |
The system will show the diagnostic address of any input that changes. Pushing the Enter Button will navigate to that address to display the status of that input. |
| Header E01 |
10 |
_ _ _ _ |
_ nn.n |
DISPLAY: Electronic Power (cc# 021) voltage. This is used to power the logic circuits of the control unit. |
Analog voltage shown in Volts DC. Battery Voltage |
| Header E01 |
11 |
_ _ _ _ |
nn.nn |
DISPLAY: CAN Lo (cc# 964) voltage |
Analog voltage shown in Volts DC |
| Header E01 |
12 |
_ _ _ _ |
nn.nn |
DISPLAY: CAN Hi (cc# 965) voltage |
Analog voltage shown in Volts DC |
| Header E01 |
13 |
_ _ _ _ |
_ nn.n |
DISPLAY: Control Circuit Power 2 (cc# 045) voltage to Header Control Unit at X205, Pin K3. This is used to power the valve driver circuits of the control unit. |
Analog voltage shown in Volts DC |
| Header E01 |
14 |
_ _ _ _ |
_nn.n |
DISPLAY: Control Circuit Power 2 (cc# 045) voltage to Header Control Unit at X205, Pin E3. This is used to power the reel valve driver circuits of the control unit. |
Analog voltage shown in Volts DC. Battery voltage. Engine must be running. |
| Header E01 |
15 |
_ _ _ _ |
_ n.nn |
DISPLAY: Height Sensor Power (cc# 481) voltage. This is used to power the HEADERTRAK Return to Cut Sensor and Header Height Sensors |
Analog voltage shown in Volts DC. 4.8 - 5.2 V is normal. |
| Header E01 |
16 |
_ _ _ _ |
_ n.nn |
DISPLAY: Height Sensor Power 2 (cc# 471) voltage. This is used to power the HEADERTRAK - Tilt Angle Sensor |
Analog voltage shown in Volts DC. 4.8 - 5.2 V is normal. |
| Header E01 |
17 |
_ _ _ _ |
nn.nn |
DISPLAY: Return to Cut Sensor (cc# 828) |
Analog voltage shown in Volts DC |
| Header E01 |
18 |
_ _ _ _ |
nn.nn |
DISPLAY: HEADERTRAK - Tilt Angle Sensor (cc# 833) |
Analog voltage shown in Volts DC |
| Header E01 |
19 |
_ _ _ _ |
nn.nn |
DISPLAY: Header Raise Pressure (cc# 706) |
Analog voltage shown in Volts DC |
| Header E01 |
20 |
_ _ _ _ |
nn.nn |
DISPLAY: Deck Plate Position Sensor or Reel Position Sensor (cc# 834) |
Analog voltage shown in Volts DC |
| Header E01 |
21 |
_ _ _ _ |
nn.nn |
DISPLAY: Reel Height Sensor (cc# 835) |
Analog voltage shown in Volts DC |
| Header E01 |
22 |
_ _ _ _ |
nn.nn |
DISPLAY: HEADERTRAK - Height Sensor 1 (Left) (cc# 412) |
Analog voltage shown in Volts DC |
| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
24 |
_ _ _ _ |
nn.nn |
DISPLAY: HEADERTRAK - Height Sensor 3, Flex Height Sensor or DIAL-A-MATIC Pad #3 (cc# 414) |
Analog voltage shown in Volts DC |
| Header E01 |
25 |
_ _ _ _ |
nn.nn |
DISPLAY: HEADERTRAK - Height Sensor 4 or DIAL-A-MATIC Pad #6 (cc# 415) |
Analog voltage shown in Volts DC |
| Header E01 |
26 |
_ _ _ _ |
nn.nn |
DISPLAY: HEADERTRAK - Height Sensor 5 (Right) (cc# 454) |
Analog voltage shown in Volts DC |
| Header E01 |
27 |
_ _ _ _ |
nn.nn |
DISPLAY: Left ultrasonic sensor or DIAL-A-MATIC Pad #1 (cc# 416) |
Analog voltage shown in Volts DC |
| Header E01 |
28 |
_ _ _ _ |
nn.nn |
DISPLAY: Right ultrasonic sensor or DIAL-A-MATIC Pad #2 (cc# 417) |
Analog voltage shown in Volts DC |
| Header E01 |
40 |
_ _ _ _ |
nnnn |
DISPLAY: Reel Speed (cc# 608) |
Shown in Hertz |
| Header E01 |
50 |
_ _ _ _ |
nnxx |
DISPLAY: Header type indicated by select lines |
0 = no header connected 2 = Row Crop Header w/ Contacting Height Sensors 3 = Row Crop w/ DIAL-A-MATICSensor 4 = Corn Head w/ Contacting or Noncontacting Height Sensors 8 = Rigid Platform 12 = Flex Platform w/ Contacting Height Sensors 13 = Flex Platform w/ DIAL-A-MATICSensor |
| Header E01 |
50 |
_ _ _ _ |
xxnn |
DISPLAY: Header type selected by controller |
0 = no header connected 2 = Row Crop Header w/ Contacting Height Sensors 3 = Row Crop w/ DIAL-A-MATICSensor 4 = Corn Head w/ Contacting or Noncontacting Height Sensors 8 = Rigid Platform 12 = Flex Platform w/ Contacting Height Sensors 13 = Flex Platform w/ DIAL-A-MATICSensor |
| Header E01 |
51 |
_ _ _ _ |
_ nnn |
DISPLAY: Left ultrasonic digital value |
Range = 0 - 255 |
| Header E01 |
52 |
_ _ _ _ |
_ nnn |
DISPLAY: Right ultrasonic digital value |
Range = 0 - 255 |
| Header E01 |
53 |
_ _ _ 1 |
xxxx |
DISPLAY: DIAL-A-MATICSensor inputs |
1 = Pad 3 (header off ground) active 0 = Pad not active 3 = undefined input |
| Header E01 |
53 |
_ _ _ x |
1xxx |
DISPLAY: DIAL-A-MATICSensor inputs |
1 = Pad 2 active 0 = Pad not active 3 = undefined input |
| Header E01 |
53 |
_ _ _ x |
x1xx |
DISPLAY: DIAL-A-MATICSensor inputs |
1 = Pad 1 active 0 = Pad not active 3 = undefined input |
| Header E01 |
53 |
_ _ _ x |
xx1x |
DISPLAY: DIAL-A-MATICSensor inputs |
1 = Pad 6 active 0 = Pad not active 3 = undefined input |
| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
53 |
_ _ _ x |
xxx1 |
DISPLAY: DIAL-A-MATICSensor inputs |
1 = Pad 5 (header down hard on ground) active 0 = Pad not active 3 = undefined input |
| Header E01 |
60 |
_ _ 1x |
xxxx |
DISPLAY: CAN Bus message from Armrest Control Unit - Tilt Left Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
60 |
_ _ x1 |
xxxx |
DISPLAY: CAN Bus message from Armrest Control Unit - Tilt Right Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
60 |
_ _ xx |
1xxx |
DISPLAY: CAN Bus message from Armrest Control Unit - Header Raise Fast Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
60 |
_ _ xx |
x1xx |
DISPLAY: CAN Bus message from Armrest Control Unit - Header Raise Slow Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
60 |
_ _ xx |
xx1x |
DISPLAY: CAN Bus message from Armrest Control Unit - Header Lower Fast Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
60 |
_ _ xx |
xxx1 |
DISPLAY: CAN Bus message from Armrest Control Unit - Header Lower Slow Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
61 |
_ _ _ _ |
1xxx |
DISPLAY: CAN Bus message from Armrest Control Unit - Reel Fore Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
61 |
_ _ _ _ |
x1xx |
DISPLAY: CAN Bus message from Armrest Control Unit - Reel Aft Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
61 |
_ _ _ _ |
xx1x |
DISPLAY: CAN Bus message from Armrest Control Unit - Reel Raise Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
61 |
_ _ _ _ |
xxx1 |
DISPLAY: CAN Bus message from Armrest Control Unit - Reel Lower Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
62 |
_ _ _ _ |
1xxx |
DISPLAY: CAN Bus message from Armrest Control Unit - Header Engaged |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
62 |
_ _ _ _ |
x1xx |
DISPLAY: CAN Bus message from Armrest Control Unit - HEADERTRAK Activation Button 3 |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
62 |
_ _ _ _ |
xx1x |
DISPLAY: CAN Bus message from Armrest Control Unit - HEADERTRAK Activation Button 2 |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
62 |
_ _ _ _ |
xxx1 |
DISPLAY: CAN Bus message from Armrest Control Unit - HEADERTRAK Activation Button 1 |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
63 |
_ _ 1x |
xxxx |
DISPLAY: CAN Bus message from Armrest Control Unit - HYDRAFLEXPressure Increase Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
63 |
_ _ x1 |
xxxx |
DISPLAY: CAN Bus message from Armrest Control Unit - HYDRAFLEXPressure Decrease Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
63 |
_ _ xx |
1xxx |
DISPLAY: CAN Bus message from Armrest Control Unit - Reel Speed Increase Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
63 |
_ _ xx |
x1xx |
DISPLAY: CAN Bus message from Armrest Control Unit - Reel Speed Decrease Button |
1 = message received that switch is pushed 0 = no message received or message received that switch is released |
| Header E01 |
63 |
_ _ xx |
xx1x |
DISPLAY: CAN Bus message from Armrest Control Unit - Road/Field Status |
1 = message received that combine is in Road mode 0 = no message received or message received that combine is in Field mode |
| Header E01 |
63 |
_ _ xx |
xxx1 |
DISPLAY: CAN Bus message from Armrest Control Unit - Dump Valve Request |
1 = message received that dump valve activation is requested 0 = no message received or message received that dump valve request is cancelled |
| Header E01 |
64 |
_ _ _ _ |
_ nnn |
DISPLAY: CAN Bus message from Armrest Control Unit - HEADERTRAK Height Encoder value |
Clockwise rotation increases value. Counterclockwise rotation decreases value. Range = 0 - 255 |
| Header E01 |
65 |
_ _ _ _ |
_ nnn |
DISPLAY: CAN Bus message from Armrest Control Unit - HEADERTRAK Sensitivity Adjust setting |
Clockwise rotation increases value. Counterclockwise rotation decreases value. Range = 0 - 100 |
| Header E01 |
66 |
_ _ _ _ |
_ nnn |
DISPLAY: CAN Bus message from Armrest Control Unit - HEADERTRAK Rate Adjust setting |
Clockwise rotation increases value. Counterclockwise rotation decreases value Range = 0 - 100 |
| Header E01 |
67 |
_ _ _ _ |
_ nnn |
DISPLAY: CAN Bus message from Armrest Control Unit - DIAL-A-SPEED Encoder value |
Clockwise rotation increases value. Counterclockwise rotation decreases value. Range = 0 - 11 0 = minimum reel speed 11 = maximum reel speed |
| Header E01 |
70 |
_ _ _ _ |
1xxx |
DISPLAY: CAN Bus message from Cornerpost Control Unit - header lift valve type |
1 = Proportional Valve |
| Header E01 |
70 |
_ _ _ _ |
x1xx |
DISPLAY: CAN Bus message from Cornerpost Control Unit - header lift valves |
1 = two valves |
| Header E01 |
70 |
_ _ _ _ |
xx1x |
DISPLAY: CAN Bus message from Cornerpost Control Unit - reel lift valve type |
1 = separate reel lift and reel lower valves 0 = single reel height valve |
| Header E01 |
70 |
_ _ _ _ |
xxx1 |
DISPLAY: CAN Bus message from Cornerpost Control Unit - measurement units |
1 = metric units 0 = English units |
| Header E01 |
71 |
_ _ _ 1 |
xxxx |
DISPLAY: CAN Bus message from Cornerpost Control Unit - Option Availability - HEADERTRAK - Stubble Height |
1 = option is installed 0 = option is not installed. |
| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
71 |
_ _ _ x |
1xxx |
DISPLAY: CAN Bus message from Cornerpost Control Unit - Option Availability - HEADERTRAK - Tilt |
1 = option is installed 0 = option is not installed. |
| Header E01 |
71 |
_ _ _ x |
x1xx |
DISPLAY: CAN Bus message from Cornerpost Control Unit - Option Availability - HEADERTRAK - Ground Pressure |
1 = option is installed 0 = option is not installed. |
| Header E01 |
71 |
_ _ _ x |
xx1x |
DISPLAY: CAN Bus message from Cornerpost Control Unit - Option Availability - Reel Resume |
1 = option is installed 0 = option is not installed. |
| Header E01 |
71 |
_ _ _ x |
xxx1 |
DISPLAY: CAN Bus message from Cornerpost Control Unit - Option Availability - DIAL-A-SPEED |
1 = option is installed 0 = option is not installed. |
| Header E01 |
72 |
_ _ 1x |
xxxx |
DISPLAY: CAN Bus message from Cornerpost Control Unit - HEADERTRAK - Stubble Height Enabled |
1 = enabled 0 = no message received or message received that option is not enabled |
| Header E01 |
72 |
_ _ x1 |
xxxx |
DISPLAY: CAN Bus message from Cornerpost Control Unit - Header Flotation enabled |
1 = enabled 0 = no message received or message received that option is not enabled |
| Header E01 |
72 |
_ _ xx |
1xxx |
DISPLAY: CAN Bus message from Cornerpost Control Unit - HEADERTRAK - Tilt enabled |
1 = enabled 0 = no message received or message received that option is not enabled |
| Header E01 |
72 |
_ _ xx |
x1xx |
DISPLAY: CAN Bus message from Cornerpost Control Unit - HEADERTRAK - Stubble Height enabled |
1 = enabled 0 = no message received or message received that option is not enabled |
| Header E01 |
72 |
_ _xx |
xx1x |
DISPLAY: CAN Bus message from Cornerpost Control Unit - Reel Resume enabled |
1 = enabled 0 = no message received or message received that option is not enabled |
| Header E01 |
72 |
_ _xx |
xx1x |
DISPLAY: CAN Bus message from Cornerpost Control Unit - DIAL-A-SPEED enabled |
1 = enabled 0 = no message received or message received that option is not enabled |
| Header E01 |
73 |
_ _ _ _ |
nnn.n |
DISPLAY: CAN Bus message from Engine Control Unit - Engine Speed |
rpm |
| Header E01 |
74 |
_ _ _ _ |
_ nn.n |
DISPLAY: CAN Bus message from Left Control Unit - Ground Speed |
Miles per hour or Kilometers per hour |
| Header E01 |
75 |
_ _ _ _ |
_ nn.n |
DISPLAY: Reel Speed |
Miles per hour or Kilometers per hour |
| Header E01 |
100 |
_ _ _ _ |
_ _ _ _ |
CALIBRATION: Factory Interactive Calibration Mode |
|
| Header E01 |
101 |
_ _ _ _ |
_ _ _ _ |
CALIBRATION: Header Interactive Calibration Mode |
|
| Header E01 |
102 |
_ _ _ _ |
_ _ _ _ |
CALIBRATION: HEADERTRAK - Tilt Interactive Calibration Mode |
|
| Header E01 |
103 |
_ _ _ _ |
_ _ _ _ |
CALIBRATION: HEADERTRAK - Ground Pressure Interactive Calibration Mode |
|
| Header E01 |
104 |
_ _ _ _ |
_ _ _ _ |
CALIBRATION: Adjustable Deck Plate Interactive Calibration Mode |
|
| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
110 |
_ _ _ _ |
_ n.nn |
DISPLAY/MODIFY: Manual header raise time to disable HEADERTRAK features. Not modifiable when engine is running. |
Shown in seconds. Range = 0.50 - 2.50 Default = 1.50 |
| Header E01 |
111 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Deadband for HEADERTRAK - Tilt algorithm. Not modifiable when engine is running. |
Range = 50 - 250 Default = 150 |
| Header E01 |
112 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Deadband for HEADERTRAK - Stubble Height algorithm. Not modifiable when engine is running. |
Range = 50 - 250 Default = 105 |
| Header E01 |
113 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Deadband for HEADERTRAK - Return to Cut algorithm. Not modifiable when engine is running. |
Range = 50 - 250 Default = 90 |
| Header E01 |
114 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Threshold for Drop Rate Valve |
Range = 50 - 250 Default = 100 |
| Header E01 |
115 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Gain for HEADERTRAK - Tilt algorithm |
Increase number to slow response of HEADERTRAK - Tilt to changes Range = 2-8 Default = 6 |
| Header E01 |
116 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: HEADERTRAK - Return to Cut display range |
Range = 0 - 3000 mm or 0 - 99.9 inches Default = set by header type |
| Header E01 |
117 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: HEADERTRAK - Stubble Height display range |
Range = 0 - 3000 mm or 0 - 99.9 inches Default = set by header type |
| Header E01 |
118 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Ultrasonic Sensor offset |
Number adjusts the level position of the header when HEADERTRAK - Tilt is using Non-Contacting Sensors (Ultrasonic). To lower left end - decrease number. To lower right end - increase number Range = 0 - 100 Default = 50 (no offset) |
| Header E01 |
119 |
_ _ _ _ |
nnnn |
DISPLAY/MODIFY: DIAL-A-SPEED transfer function |
Ratio of reel speed frequency to reel tip velocity Range = 1200 - 2200 Default = 1892 |
| Header E01 |
120 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Minimum reel speed for DIAL-A-SPEED |
Range = 1.6 - 5.0 km/h or 1.0 - 3.2 mph |
| Header E01 |
121 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Maximum reel speed for DIAL-A-SPEED |
Range = 8.0 - 16.0 km/h or 5.0 - 10.0 mph |
| Header E01 |
122 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Select DIAL-A-SPEED numerical display on Cornerpost Display Unit 3 |
1 = display Reel Speed to Ground Speed offset in km/h or mph. The offset is operator adjustable with the DIAL-A-SPEED Encoder 0 = display Reel Speed to Ground Speed as ratio. The ratio is operator adjustable with the DIAL-A-SPEED Encoder Default = 0 |
| Header E01 |
123 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Cutterbar height setpoint for HEADERTRAK - Ground Pressure |
Range = 0 - 250 Default = 35 |
| Header E01 |
124 |
_ _ _ _ |
_ _ _ n |
DISPLAY/MODIFY: Activation Button 2 operation mode select |
0 = HEADERTRAK - Stubble Height 1 = HEADERTRAK - Return to Cut |
| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
125 |
_ _ _ _ |
nnnn |
CALIBRATION: Header Width |
Range for cutting platforms = 0 - 60 meters or 0 - 200 feet Range for row crop or corn heads = 0 - 9999 mm or 0 - 2400 inches |
| Header E01 |
126 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: DIAL-A-SPEED algorithm deadband |
Range = 50 - 250 Default = 128 |
| Header E01 |
127 |
_ _ _ _ |
_ _ _ n |
DISPLAY/MODIFY: Header Fast Raise for HYDRAFLEX Platforms only |
1 = Slow and Fast Raise will be used as required by HEADERTRAK - Stubble Height 0 = only Fast Raise will be used by HEADERTRAK - Stubble Height |
| Header E01 |
128 |
_ _ _ _ |
_ nnn |
DISPLAY/MODIFY: Height valve command - algorithm gain |
Increase number to increase reaction Decrease number to increase system stability Range = 50 - 250 Default = 120 |
| Header E01 |
129 |
_ _ _ _ |
_ _ _ n |
DISPLAY/MODIFY: HEADERTRAK Ground Pressure algorithm gain |
Increase number to increase reaction Decrease number to increase system stability Range = 1 - 5 Default = 3 |
| Header E01 |
130 |
_ _ _ _ |
_ nxx |
DISPLAY: Height valve command - direction |
0 = Output off 1 = Raise 2 = Lower |
| Header E01 |
130 |
_ _ _ _ |
_ xnn |
DISPLAY: Height valve command - speed |
Shown in percent Range = 0 - 99 |
| Header E01 |
131 |
_ 1xx |
xxxx |
DISPLAY: Tilt Left Valve command |
1 = output to valve turned on 0 = Output off |
| Header E01 |
131 |
_ x1x |
xxxx |
DISPLAY: Tilt Right Valve command |
1 = output to valve turned on 0 = Output off |
| Header E01 |
131 |
_ xx1 |
xxxx |
DISPLAY: Dump Valve command |
1 = output to valve turned on 0 = Output off |
| Header E01 |
131 |
_ xxx |
1xxx |
DISPLAY: Reel Fore Valve command |
1 = output to valve turned on 0 = Output off |
| Header E01 |
131 |
_ xxx |
x1xx |
DISPLAY: Reel Aft Valve command |
1 = output to valve turned on 0 = Output off |
| Header E01 |
131 |
_ xxx |
xx1x |
DISPLAY: Reel Raise Valve command (used with Dump Valve Command) |
1 = output to valve turned on 0 = Output off |
| Header E01 |
131 |
_ xxx |
xxx1 |
DISPLAY: Reel Lower Valve command |
1 = Output to valve turned on 0 = Output off |
| Header E01 |
132 |
_ _ _ _ |
_ 1xx |
DISPLAY: HYDRAFLEX Pressure Select Valve command |
1 = Output to valve turned on 0 = Output off |
| Header E01 |
132 |
_ _ _ _ |
_ x1x |
DISPLAY: Accumulator Shutoff Valve command |
1 = Output to valve turned on 0 = Output off |
| Header E01 |
132 |
_ _ _ _ |
_ xx1 |
DISPLAY: Header Drop Rate Valve command |
1 = Output to valve turned on 0 = Output off |
| Header E01 |
133 |
_ _ _ _ |
_ nxx |
DISPLAY: Reel speed motor command - direction |
0 = motor off 1 = increasing 2 = decreasing |
| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
133 |
_ _ _ _ |
_ xnn |
DISPLAY: Reel speed motor command - speed |
Shown in percent Range = 0 - 99 |
| Header E01 |
140 |
_ _ _ 1 |
xxxx |
DISPLAY: Flex Height Sensor |
1 = HEADERTRAK System recognizes sensors due to input from sensors greater than 0.5 V DC 0 = HEADERTRAK System does not recognize sensors due to input from sensors less than 0.5 V DC |
| Header E01 |
140 |
_ _ _ x |
1xxx |
DISPLAY: Non-Contacting Height Sensors (Ultrasonic) |
1 = HEADERTRAK System recognizes sensors due to digital data stream from sensors 0 = HEADERTRAK System does not recognize sensors due to lack of digital data stream from sensors. |
| Header E01 |
140 |
_ _ _ x |
x1xx |
DISPLAY: Deck Plate Spacing Sensor |
1 = HEADERTRAK System recognizes sensors due to input from sensors greater than 0.5 V DC 0 = HEADERTRAK System does not recognize sensors due to input from sensors less than 0.5 V DC |
| Header E01 |
140 |
_ _ _ x |
xx1x |
DISPLAY: Center HEADERTRAK - Height Sensor |
1 = HEADERTRAK System recognizes sensors due to input from sensors greater than 0.5 V DC 0 = HEADERTRAK System does not recognize sensors due to input from sensors less than 0.5 V DC |
| Header E01 |
140 |
_ _ _ x |
xxx1 |
DISPLAY: Contacting HEADERTRAK - Height Sensors |
1 = HEADERTRAK System recognizes sensors due to input from sensors greater than 0.5 V DC 0 = HEADERTRAK System does not recognize sensors due to input from sensors less than 0.5 V DC |
| Header E01 |
141 |
_ _ _ n |
xxxx |
DISPLAY: Height Sensor Override. Height sensor override will prevent a header from hitting the ground while in the return-to-cut mode by automatically raising the header whenever the height sensors touch the ground. |
0 = normal 1 = override |
| Header E01 |
141 |
_ _ _ x |
nxxx |
DISPLAY: Harvesting status. Machine harvesting status based on an operator adjustable feeder house angle threshold. When the feeder house is below the threshold, the machine is harvesting, and when the feeder house is above the threshold, the machine is not harvesting. |
0 = not harvesting 1 = harvesting |
| Header E01 |
141 |
_ _ _ x |
xnxx |
DISPLAY: HEADERTRAK - Tilt operating mode |
0 = Off 2 = Manual tilt right 3 = Manual tilt left 4 = Automatic tilt mode 5 = Automatic tilt mode with ultrasonics |
| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
141 |
_ _ _ x |
xxnn |
DISPLAY: Height Control operating mode |
0 = Off 1 = Open loop enable mode 2 = Open loop slow raise mode 3 = Open loop slow lower mode 4 = Open loop fast raise mode 5 = Open loop fast lower mode 6 = Manual enable mode 7 = Manual slow raise mode 8 = Manual slow lower mode 9 = Manual fast raise mode 10 = Manual fast lower mode 11 = HEADERTRAK Return to Cut enable mode 12 = HEADERTRAK Stubble Height initial mode 13 = HEADERTRAK Stubble Height enable mode 14 = HEADERTRAK - Ground Pressure initial mode 15 = HEADERTRAK - Ground Pressure enable mode 16 = Open loop slow lower override mode 17 = Open loop slow raise override mode |
| Header E01 |
142 |
_ _ _ _ |
nxxx |
DISPLAY: Header Flotation operating mode |
0 = HEADERTRAK - Ground Pressure disabled 1 = Manual HEADERTRAK - Ground Pressure Enable 2 = Manual HEADERTRAK - Ground Pressure Increase 3 = Manual HEADERTRAK - Ground Pressure Decrease 6 = HEADERTRAK - Ground Pressure - Activation Button 1 7 = HEADERTRAK - Ground Pressure - Activation Button 2 8 = HEADERTRAK - Ground Pressure - Activation Button 3 |
| Header E01 |
142 |
_ _ _ _ |
xnxx |
DISPLAY: DIAL-A-SPEED operating mode |
0 = DIAL-A-SPEED disabled 1 = Manual Enable 2 = Manual Speed Increase 3 = Manual Speed Decrease |
| Header E01 |
142 |
_ _ _ _ |
xxnx |
DISPLAY: Reel Resume - Fore/Aft operating mode |
0 = disabled 1 = Manual Enable 2 = Manual Reel Fore 3 = Manual Reel Aft 6 = Reel Resume - Activation Button 1 7 = Reel Resume - Activation Button 2 8 = Reel Resume - Activation Button 3 |
| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
142 |
_ _ _ _ |
xxxn |
DISPLAY: Reel Resume - Raise/Lower operating mode |
0 = off 1 = Manual Enable 4 = Manual Reel Raise 5 = Manual Reel Lower 6 = Reel Resume - Activation Button 1 7 = Reel Resume - Activation Button 2 8 = Reel Resume - Activation Button 3 |
| Header E01 |
143 |
_ _ _ n |
nnnn |
DISPLAY: Failure overriding modes. This number is the sum of all failure modes existing at once. |
0 = Normal 1 = Shut off raise/lower valves due to valve driver problems 2 = Shut off tilt valves 4 = No HEADERTRAK - Stubble Height 8 = No HEADERTRAK - Stubble Height, Ground Pressure, or Height Resume 16 = No HEADERTRAK - Stubble Height 32 = No HEADERTRAK - Ground Pressure 64 = No HEADERTRAK - Tilt 128 = No HEADERTRAK - Tilt with non-contacting (ultrasonic) sensors 256 = No Reel Resume Raise/Lower for Activation Button 1 512 = No Reel Resume Fore/Aft for Activation Button 1 1024 = No Reel Resume Raise/Lower for Activation Button 2 2048 = No Reel Resume Fore/Aft for Activation Button 2 4096 = No Reel Resume Raise/Lower for Activation Button 3 8192 = No Reel Resume Fore/Aft for Activation Button 3 |
| Header E01 |
144 |
_ _ _ _ |
_ nnn |
DISPLAY: Feeder House position command |
Command by controller Range = 0 - 127 |
| Header E01 |
145 |
_ _ _ _ |
_ nnn |
DISPLAY: Position set point |
Set by rotating Height Control Encoder Range = 0 - 127 |
| Header E01 |
146 |
_ _ _ _ |
_ nnn |
DISPLAY: Feeder House position |
Input from HEADERTRAK Return to Cut Sensor Range = 0 - 127 |
| Header E01 |
147 |
_ _ _ _ |
_ nnn |
DISPLAY: HEADERTRAK - Height |
Input from HEADERTRAK - Height Sensor Range = 0 - 127 |
| Header E01 |
148 |
_ _ _ _ |
_ nnn |
DISPLAY: Header tilt position (left - right) from HEADERTRAK - Tilt Sensor |
Input from HEADERTRAK - Tilt Sensor 0 = level As the right end goes down the number increases from 0 towards 127 As the left end goes down, the numbers decrease from 255 towards 128 (Left Down) 128 - - 191 - - 255/0 - - 63 - - 127 (Right Down) |
| Control Unit |
Add. |
Line 2 |
Line 3 |
Description |
Details |
| Header E01 |
149 |
_ _ _ _ |
_ nnn |
DISPLAY: Header tilt position (left - right) from Non-Contacting HEADERTRAK - Height Sensor (Ultrasonic) |
Input from Non-Contacting HEADERTRAK - Height Sensor (Ultrasonic) 0 = level As the right end goes down the number increases from 0 towards 127 As the left end goes down, the numbers decrease from 255 towards 128 (Left Down) 128 - - 191 - - 255/0 - - 63 - - 127 (Right Down) |
| Header E01 |
150 |
nnnn |
xxxx |
DISPLAY: Header raise valve current |
Shown in milliamperes. Range = 0 - 3400 |
| Header E01 |
150 |
xxxx |
nnnn |
DISPLAY: Header lower valve current |
Shown in milliamperes. Range = 0 - 3400 |
| Header E01 |
151 |
_ _ _ _ |
_ nnn |
DISPLAY: Lift cylinder pressure |
Shown in bar (kPa = bar x 100) (PSI = bar / 0.06894) |
| Header E01 |
152 |
_ _ _ n |
nnnn |
DISPLAY: calibrated header types |
List of calibrated headers by type. Rotate encoder to scroll through list. Top line of display is header number. Bottom line of display is header type. 0 = n/a 1 = n/a 2 = Row Crop Header w/ Contacting Height Sensors 3 = Row Crop 4 = Corn Head w/ Contacting Height Sensors 5 = n/a 8 = Rigid Platform 9 = n/a 11 = n/a 12 = Flex Platform w/ Contacting Height Sensors 13 = Flex Platform w/ DIAL-A-MATICSensor 14 = no header connected 15 = n/a |
| Header E01 |
157 |
_ _ _ _ |
nnnn |
DISPLAY: HYDRAFLEX Pressure |
Shown in bar (kPa = bar x 100) (PSI = bar / 0.06894) |
| Header E01 |
227 |
_ _ nn |
nnnn |
DISPLAY: Part number of the boot block program |
|
| Header E01 |
228 |
_ _ _ _ |
_ nn.n |
DISPLAY: Version number of the boot block program |
|
| Header E01 |
233 |
_ _ nn |
nnnn |
DISPLAY: Base program part number |
|
| Header E01 |
234 |
_ _ _ _ |
nnn.n |
DISPLAY: Base program version number |
|
| Header E01 |
235 |
_ _ nn |
nnnn |
DISPLAY: Device part number |
|