E02 Right Control Unit

Diagnostic Addresses - E02 Right Control Unit

Control Unit Add. Line 2 Line 3 Description Details
Right E02 1 nnnn nn.nn Diagnostic Trouble Codes "none" - indicates there are no Diagnostic Trouble Codes.
"code" - indicates there are Diagnostic Trouble Codes available.
Push ENTER button to view codes. Use ARROW-UP and ARROW-DOWN to scroll through list of codes.
Right E02 2 _ _ _ _ nnnn BEEP: Right Control Unit Beep Mode The system will show the diagnostic address of any input that changes. Pushing the Enter Button will navigate to that address to display the status of that input.
Right E02 3 _ _ _ _ nnnn BEEP: Right Control Unit Beep Mode w/o Grain Loss Sensors The system will show the diagnostic address of any input that changes. Changes or strikes on the Visiontrak system are ignored. Pushing the Enter Button will navigate to that address to display the status of that input.
Right E02 10 _ _ _ _ nn.nn DISPLAY: Electronic Power (cc# 021) voltage Analog voltage shown in Volts DC
Right E02 11 _ _ _ _ nn.nn DISPLAY: CAN Lo (cc# 964) voltage Analog voltage shown in Volts DC
Right E02 12 _ _ _ _ nn.nn DISPLAY: CAN Hi (cc# 965) voltage Analog voltage shown in Volts DC
Right E02 13 _ _ _ _ nn.nn DISPLAY: Main Gearcase Oil Temperature Signal (cc# 774) voltage Analog voltage shown in Volts DC
Right E02 14 _ _ _ _ nn.nn DISPLAY: Hydraulic Oil Temperature Signal (cc# 775) voltage Analog voltage shown in Volts DC
Right E02 15 _ _ _ _ nn.nn DISPLAY: Fuel Level Signal (cc# 652) voltage Analog voltage shown in Volts DC
Right E02 16 _ _ _ _ _ nn.n DISPLAY: Right Control Unit Sensor Power (cc# 781) voltage (9880STS only) Analog voltage shown in Volts DC
Right E02 17 _ _ _ _ nn.nn DISPLAY: Vane Angle Position Signal voltage (cc# 781) Analog voltage shown in Volts DC
Right E02 30 _ _ _ _ nnnn DISPLAY: Right Shoe Sensor strike count Entering the diagnostic mode zeroes the counts at addresses 030, 031, 032, and 033. Strikes on each Visiontrak sensor are counted. This address displays the Right Shoe Sensor strike count.
Right E02 31 _ _ _ _ nnnn DISPLAY: Left Shoe Sensor strike count Entering the diagnostic mode zeroes the counts at addresses 030, 031, 032, and 033. Strikes on each Visiontrak sensor are counted. This address displays the Left Shoe Sensor strike count.

 

OUZXMAG,00018B1 -19-10OCT02-1/4


Control Unit Add. Line 2 Line 3 Description Details
Right E02 32 _ _ _ _ nnnn DISPLAY: Right Separator Sensor strike count Entering the diagnostic mode zeroes the counts at addresses 030, 031, 032, and 033. Strikes on each Visiontrak sensor are counted. This address displays the Right Separator Sensor strike count.
Right E02 33 _ _ _ _ nnnn DISPLAY: Left Separator Sensor strike count Entering the diagnostic mode zeroes the counts at addresses 030, 031, 032, and 033. Strikes on each Visiontrak sensor are counted. This address displays the Left Separator Sensor strike count.
Right E02 50 _ _ _ _ xxx1 DISPLAY: CAN Message from Armrest Control Unit - Header Engaged 1 = engaged
0 = disengaged
3 = undefined
Right E02 60 nnnn _ _ _ _ DISPLAY: Main Gearcase Oil Temperature Temperature shown in °C or °F
Right E02 61 nnnn _ _ _ _ DISPLAY: Hydraulic Oil Temperature Temperature shown in °C or °F
Right E02 62 _ _ _ _ _ nnn DISPLAY: Fuel Level Shown as percent of fuel tank
0 = empty
100 = full
Right E02 63 _ _ _ _ nn.nn DISPLAY: Chopper Vane Angle Shown as degrees
Range = -5 (left) to 5 (right)
Right E02 64 _ _ _ _ nnnn DISPLAY: Combine Model Year  
Right E02 65 _ _ _ _ nnnn DISPLAY: Can Bus message from Left Control Unit - Ground Speed Shown in km/h or mph
Right E02 100 _ _ _ _ _ _ nn DISPLAY/MODIFY: Grain Loss Calibration Value Increase number to lower system sensitivity to loss. Decrease number to raise system sensitivity to loss.
Range = 0 - 99
Default = 25
Right E02 101 _ _ _ _ _ _ _ n DISPLAY/MODIFY: Seed Size 1 = small seed
2 = medium seed
3 = large seed
Right E02 102 _ _ _ _ _ _ _ n DISPLAY/MODIFY: Shoe Display 0= Off
1 = left and right sensors are averaged
2 = left and right sensors are shown independently
Right E02 103 _ _ _ _ _ _ _ n DISPLAY/MODIFY: Separator Display 0= Off
1 = left and right sensors are averaged
2 = left and right sensors are shown independently
Right E02 104 _ _ _ _ _ _nn DISPLAY/MODIFY: Shoe offset Increase number to lower displayed level of shoe loss. Decrease number to raise displayed level of shoe loss.
Range = 50 - 250
Default = 40
Right E02 105 _ _ _ _ _ nnn DISPLAY/MODIFY: Separator offset Increase number to lower displayed level of separator loss. Decrease number to raise displayed level of separator loss.
Range = 50 - 250
Default = 40

 

OUZXMAG,00018B1 -19-10OCT02-2/4


Control Unit Add. Line 2 Line 3 Description Details
Right E02 106 _ _ _ _ _ _nn DISPLAY/MODIFY: Small Seed Size Threshold Increase number to raise sensor sensitivity to strikes. Decrease number to lower sensor sensitivity to strikes.
Range = 20 - 38
Default = 27
Right E02 107 _ _ _ _ _ _nn DISPLAY/MODIFY: Medium Seed Size Threshold Increase number to raise sensor sensitivity to strikes. Decrease number to lower sensor sensitivity to strikes.
Range = 20 - 38
Default = 27
Right E02 108 _ _ _ _ _ _nn DISPLAY/MODIFY: Large Seed Size Threshold Increase number to raise sensor sensitivity to strikes. Decrease number to lower sensor sensitivity to strikes.
Range = 20 - 38
Default = 27
Right E02 109 _ _ _ _ _ nnn DISPLAY/MODIFY: Shoe small scaling factor If the scaling factor is increased, the relative display increases.
Range = 50 - 250
Default = 127
Right E02 110 _ _ _ _ _ nnn DISPLAY/MODIFY: Shoe medium scaling factor If the scaling factor is increased, the relative display increases.
Range = 50 - 250
Default = 115
Right E02 111 _ _ _ _ _ nnn DISPLAY/MODIFY: Shoe large scaling factor If the scaling factor is increased, the relative display increases.
Range = 50 - 250
Default = 189
Right E02 112 _ _ _ _ _ nnn DISPLAY/MODIFY: Separator small scaling factor If the scaling factor is increased, the relative display increases.
Range = 50 - 250
Default = 120
Right E02 113 _ _ _ _ _ nnn DISPLAY/MODIFY: Separator medium scaling factor If the scaling factor is increased, the relative display increases.
Range = 50 - 250
Default = 115
Right E02 114 _ _ _ _ _ nnn DISPLAY/MODIFY: Separator large scaling factor If the scaling factor is increased, the relative display increases.
Range = 50 - 250
Default = 189
Right E02 115 _ _ _ _ _ nnn CALIBRATION: Chopper Vane Angle Interactive Calibration  
Right E02 116 _ _ _ _ _ nn.n DISPLAY/MODIFY: Ground Speed at time of calibration Shown in km/h or mph
Range is 0.1 - 99.9
Default = 3.0
Right E02 117 _ _ _ _ _ nn.n DISPLAY/MODIFY: Calibration Scaling Factor Range is 0.1 - 99.9
Default = 20.0
Right E02 118 _ _ _ _ _ nn.n DISPLAY/MODIFY: Grain Loss Algorithm 0 = Speed based Algorithm (Default)
1 = Area based algorithm for all machines
2 = Speed based algorithm for all machines

 

OUZXMAG,00018B1 -19-10OCT02-3/4


Control Unit Add. Line 2 Line 3 Description Details
Right E02 119     DISPLAY: Fuel tank type 0 - single or dual fuel level sensor
1 - single fuel level sensor
2 - dual fuel level sensors
Right E02 227 _ _ nn nnnn DISPLAY: Part number of the boot block program  
Right E02 228 _ _ _ _ nnnn DISPLAY: Version number of the boot block program  
Right E02 233 _ _ nn nnnn DISPLAY: Base program part number  
Right E02 234 _ _ _ _ nnnn DISPLAY: Base program version number  
Right E02 235 _ _ nn nnnn DISPLAY: Device part number  
Right E02 236 nnnn nnnn DISPLAY: Device serial number  
Right E02 247 _ _ _ _ _ _ nn DISPLAY: Machine Model Number 14 - 9640, 9660, 9680
16 - 9540, 9560, 9580

 

OUZXMAG,00018B1 -19-10OCT02-4/4