Air-Conditioning System

Symptom Problem Solution

Lack Of Or Insufficient Cooling.

Compressor belt off or broken.

Replace belt.

Compressor not functioning (if both the large and small hoses in the left-hand access panel are at the same temperature).

See your John Deere dealer.

High-pressure switch on - insufficient air flow across condenser.

Clean condenser. Check fan belt condition. Check engine fan belt position. Check rotary screen function. If the cause of the problem cannot be determined, see your John Deere dealer.

Low-pressure switch on - insufficient air flow across evaporator.

Clean filter. Check cab fan operation. If the cause of the problem cannot be determined, see your John Deere dealer.

Low-pressure switch on - low outside air temperature.

Move slide lever to warmer setting.

Low-pressure switch on - insufficient refrigerant level (bubbles in sight glass).

See your John Deere dealer.

Heater valve partially on - with temperature lever in max. air conditioning, feel both heater hoses on right-hand side of cab; if both are warm, valve is open.

Adjust control rod through tray opening. Move lever to OFF. Loosen set screw in balljoint and when applying slight pressure down on rod, tighten balljoint.

Bad smell (foul odor) in cab.

Plugged drain tube. Dirty filters. Dirty cab.

Blow out condensate tube and clean pan under evaporator. Clean filter. Vacuum out cab.

Be certain weep valve in condensate drain tube is installed.