ARC Addresses - Armrest Control Unit
|
|
| ARC - Armrest Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 002 |
Standard |
Beep Mode |
| 003 |
Standard |
Limited System Beep Mode |
| 004 |
Standard |
Analog Beep Mode |
| 005 |
Standard |
Digital Beep Mode |
| 015 |
Analog Input |
Access to the Battery Voltage Display in Volts |
| 016 |
Analog Input |
Access to the Reference Voltage Display in Volts |
| 017 |
Analog Input |
Access to the Lamp Voltage Display in Volts |
| 018 |
Analog Input |
Access to the Row Guidance Potentiometer Display in Volts |
| 019 |
Analog Input |
Access to the CAN Low Side Voltage Display in Volts |
| 020 |
Analog Input |
Access to the CAN High Side Voltage Display in Volts |
| 021 |
Analog Input |
Access to the Cab Temperature Voltage Display in Volts |
| 022 |
Analog Input |
Access to the Outlet Temperature Voltage Display in Volts |
| 023 |
Analog Input |
Access to the Inlet Temperature Voltage Display in Volts |
| 024 |
Analog Input |
Access to the Evaporator Core Temperature Voltage Display in Volts |
| 025 |
Analog Input |
Access to the Solar Sensor Voltage Display in Volts |
| 026 |
Analog Input |
Access to the Water Valve Feedback Voltage Display in Volts |
| 050 |
Digital Input |
Digital Input 01 Following data are transmitted: Road Safety Switch, Reel Speed Increase See also "Address ARC 050 - Digital Input 01" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 051 |
Digital Input |
Digital Input 02 Following data are transmitted: Spout Rotate Left, Header Up See also "Address ARC 051 - Digital Input 02" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 052 |
Digital Input |
Digital Input 03 Following data are transmitted: Throttle Increase Button, Reel Speed Decrease, Trailer Up, Liquid Injection, Selective Control Valve I - A See also "Address ARC 052 - Digital Input 03" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
|
|
OUZXMAY,0000436 -19-26JUN02-1/5
|
| ARC - Armrest Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 053 |
Digital Input |
Digital Input 04 Following data are transmitted: Spout Rotate Right, Return to Lower Position See also "Address ARC 053 - Digital Input 04" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 054 |
Digital Input |
Digital Input 05 Following data are transmitted: Throttle Toggle Button, Spout Raise, Trailer Down, Spout Rotate Fast, Selective Control Valve I - B See also "Address ARC 054 - Digital Input 05" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 055 |
Digital Input |
Digital Input 06 Following data are transmitted: Header Down, Spout Cap Down, Spout Cap Up, Selective Control Valve II - A See also "Address ARC 055 - Digital Input 06" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 056 |
Digital Input |
Digital Input 07 Following data are transmitted: Throttle Decrease Button, Spout Lower, Header Speed Fast / Slow See also "Address ARC 056 - Digital Input 07" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 057 |
Digital Input |
Digital Input 08 Following data are transmitted: Return to Float Active, Return to Upper Position, Selective Control Valve II - B See also "Address ARC 057 - Digital Input 08" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 058 |
Digital Input |
Digital Input 09 Following data are transmitted: Pressurizer Status, Quick Stop Input, ATC Low Pressure Switch See also "Address ARC 058 - Digital Input 09" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 80 |
Display |
Cab Temperature |
| 81 |
Display |
Outlet Temperature |
| 82 |
Display |
Inlet Temperature |
| 83 |
Display |
Evaporator Temperature |
| 100 |
Input Calibration |
Spout Rotate Fast Delay Configuration Value - 0 disables spout rotate fast. Value greater than 0 - defines the delay in seconds before the armrest control unit requests spout rotate fast. Default value - 02.0 Display: ARC 100 02.0 |
|
|
OUZXMAY,0000436 -19-26JUN02-2/5
|
| ARC - Armrest Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 101 |
Input Calibration |
Fast Throttle Speed Fast throttle increase / decrease speed of the engine. Possible values: 5 - 100 The value is in terms of percent throttle/sec.. X - 40 = increase the throttle 40% in one second. Default value - 40 Display: ARC 101 40 |
| 102 |
Input Calibration |
Slow Throttle Speed Slow throttle increase / decrease speed of the engine. Possible values: 5 - 100 The value is in terms of percent throttle/sec.. X - 15 = increase the throttle 15% in one second. Default value - 15 Display: ARC 102 15 |
| 103 |
Input Calibration |
Slow Throttle Speed Hold Time The time the slow throttle speed engine acceleration is active before the high throttle engine speed acceleration becomes active. Possible values: 20 - 2000 The value is in terms of milliseconds. X - 1000 = the slow throttle speed engine acceleration for 1 second and after that use the fast throttle speed engine acceleration. Default value - 500 Display: ARC 103 500 |
| 104 |
Input Calibration |
Button 1 Configuration Used to select the function for button 3 on the multifunction lever. 0 - No function 1 - Return to pressure 2 - Return to upper position 3 - Return to lower position 4 - Row guidance enable Default value - 1 Display: ARC 104 1 |
|
|
OUZXMAY,0000436 -19-26JUN02-3/5
|
| ARC - Armrest Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 105 |
Input Calibration |
Button 2 Configuration Used to select the function for button 2 on the multifunction lever. 0 - No function 1 - Return to pressure 2 - Return to upper position 3 - Return to lower position 4 - Row guidance enable Default value - 2 Display: ARC 105 2 |
| 106 |
Input Calibration |
Button 3 Configuration Used to select the function for button 1 on the multifunction lever. 0 - No function 1 - Return to pressure 2 - Return to upper position 3 - Return to lower position 4 - Row guidance enable Default value - 3 Display: ARC 106 3 |
| 107 |
Input Calibration |
Circular Button Configuration Used to select the function for the row guidance enable switch on the multifunction lever. 0 - No function 1 - Return to pressure 2 - Return to upper position 3 - Return to lower position 4 - Row guidance enable Default value - 4 Display: ARC 107 4 |
| 119 |
Interactive Calibration |
Row Guidance Potentiometer Calibration Used to calibrate the row guidance potentiometer.NOTE: For detailed calibration procedure see "Address ARC 119 Calibration - Row Guidance Potentiometer" in this section. |
| 140 |
Digital Output |
Digital Output 01 Following data are transmitted: Header Speed Lamp, Low Idle Lamp, Mid Idle Lamp, High Idle Lamp, Spout Rotate Fast, Multi-Function-Lever Lamp, Liquid Injection Lamp, Road Switch Lamp See also "Address ARC 140 - Digital Output 01" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 141 |
Digital Output |
Digital Output 02 Following data are transmitted: Pressurizer Engage See also "Address ARC 141 - Digital Output 02" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
|
|
OUZXMAY,0000436 -19-26JUN02-4/5
|
| ARC - Armrest Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 150 |
PWM Output |
PWM Output 01 Water Valve PWM Output (X - 10 = represents 10 percent of PWM applied to the output) |
| 151 |
PWM Output |
PWM Output 02 Blower Motor PWM Output (X - 10 = represents 10 percent of PWM applied to the output) |
| 198 |
Display - Operator |
Cutterhead Operating Time |
| 199 |
Display - Operator |
Machine Operating Time |
|
|
OUZXMAY,0000436 -19-26JUN02-5/5
|
|