RCP Addresses - Corner Post Control Unit

RCP - Corner Post Control Unit
Addresses  
Number Type Description
002 Standard Beep Mode
003 Standard Limited System Beep Mode
004 Standard Analog Beep Mode
005 Standard Digital Beep Mode
010 Analog Input ATC Blower Speed Potentiometer
Display in Volts
011 Analog Input Back-Lighting Voltage Level
Display in Volts
012 Analog Input ATC Reference Voltage
Display in Volts
013 Analog Input Battery Voltage
Display in Volts
014 Analog Input ATC Temperature Set Point Potentiometer
Display in Volts
050 Digital Input Digital Input 01
Following data are transmitted: Header Raise Rate Calibration, Header Lower Rate Calibration, Sharpen Switch, Clear Switch, OBD Calibration Switch, Clock Switch
See also "Address RCP 050 - Digital Input 01"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
051 Digital Input Digital Input 02
Following data are transmitted: Kernel Processor Adjust Switch, IVLOC Switch, OBD Up Switch, OBD Down Switch
See also "Address RCP 051 - Digital Input 02"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
052 Digital Input Digital Input 03
Following data are transmitted: Row Width Switch, Number of Rows Switch, OBD Back Switch, OBD Enter Switch
See also "Address RCP 052 - Digital Input 03"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
053 Digital Input Digital Input 04
Following data are transmitted: Operating Hours Switch, Area Counter Switch, OBD Diagnostic Switch, Engine and Cutterhead Hours Switch
See also "Address RCP 053 - Digital Input 04"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
054 Digital Input Digital Input 05
Following data are transmitted: ATC On Switch, ATC Auto Switch, ATC Defog Switch, ATC Back Light Switch
See also "Address RCP 054 - Digital Input 05"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"

 

OUZXMAY,0000438 -19-26JUN02-1/4


RCP - Corner Post Control Unit
Addresses  
Number Type Description
100 Input Calibration Tire Size Calibration
Used to calibrate the tire size.
Rolling radius calibration chart for all Self-Propelled Forage Harvester
Tire size: 24.5 - 32 165 A8 - Input: 00803.0
Tire size: 620/75 R34 170 A8 - Input: 00817.0
Tire size: 650/75 R32 167 A8 - Input: 00800.0
Tire size: 650/75 R32 172 A8 - Input: 00807.0
Tire size: 800/65 R32 167 A8 - Input: 00816.0
Tire size: 800/65 R32 167 A8 - Input: 00816.0
Tire size: 900/55 R32 173 A8 - Input: 00797.0
Tire size: 1050/50 R32 174 A8 - Input: 00821.0
101 Interactive Calibration Rear Wheel Drive Control Unit Calibration
Used to calibrate the rear wheel drive control unit.

NOTE: For detailed calibration procedure see "Address RCP 101 Calibration - Rear Wheel Drive Control Unit" in this section.This teaching ratio can be displayed with address RCP 102.

102 Calibration (Read only) Rear Wheel Drive Control Unit Teaching Ratio
Displays the current rear wheel drive control unit teaching ratio.
103 Input Calibration Display Configuration (Operator)
RCP 103 ›› Ground Speed Display Units
1 - SI units (km/h)... 1XX
...XXXX

0 - English units (mph)... 0XX
...XXXX

RCP 103 ›› Pressure Display Units I
1 - SI units (bars)... X1X
...XXXX

0 - English units (PSI)...XX0X
...XXXX

RCP 103 ›› Pressure Display Units II
1 - SI units (bars)... XX1
...XXXX

0 - English units (PSI)... XX0
...XXXX

 

OUZXMAY,0000438 -19-26JUN02-2/4


RCP - Corner Post Control Unit
Addresses  
Number Type Description
    RCP 103 ›› Area Display Units
1 - SI units... XXX
...1XXX

0 - English units... XXX
...0XXX

RCP 103 ›› Linear Length Display Units
1 - SI units... XXX
...X1XX

0 - English units... XXX
...X0XX

RCP 103 ›› Enable / Disable the Clock
1 - Enables the clock... XXX
...XX1X

0 - Disables the clock... XXX
...XX0X

RCP 103 ›› Clock Display Mode
1 - 24 hour display... XXX
...XXX1

0 - 12 hour display... XXX
...XXX0

NOTE: Pressure Display Units II: This is only used if Pressure Display Units I are set to select SI units.

104 Input Calibration Operator Options
To configure the area counter and cutterhead hours function for:per fieldper dayper season cutterhead hour counterThe total cutterhead hour counter is still counting the real cutterhead hours when main clutch is engaged.
Default: The cutterhead hours per field, per day and per season are counted with the main clutch engaged.
    RCP 104 ›› Area Counter Beep
1 - Enables the area counter beep...X1XX

0 - Disables the area counter beep, Default setting...X0XX

RCP 104 ›› Cutterhead Hours Counter Activation Option 1: Feedrolls Forward Activation
1 - Activates option 1, Default setting...XX1X

0 - Deactivates option 1...XX0X

 

OUZXMAY,0000438 -19-26JUN02-3/4


RCP - Corner Post Control Unit
Addresses  
Number Type Description
    RCP 104 ›› Cutterhead Hours Counter Activation Option 2: Harvesting Position Activation
1 - Activates option 2, Default setting...XXX1

0 - Deactivates option 2...XXX0

NOTE: Option 1: The cutterhead hours are counted with the main clutch engaged AND feedrolls forward.

NOTE: Option 2: The cutterhead hours are counted with the main clutch engaged, feedrolls forward, AND the header in harvesting position.

116 Interactive Calibration Rear Wheel Drive Control Unit Pressure Sensor
Used to calibrate the rear wheel drive control unit pressure sensor.

NOTE: For detailed calibration procedure see "Address RCP 116 Calibration - Rear Wheel Drive Control Unit Pressure Sensor" in this section.

117 Interactive Calibration ATC Temperature Potentiometer Calibration
Used to calibrate the ATC temperature potentiometer.

NOTE: For detailed calibration procedure see "Address RCP 117 Calibration - ATC Temperature Potentiometer" in this section.

118 Interactive Calibration ATC Fan Potentiometer Calibration
Used to calibrate the ATC fan potentiometer.

NOTE: For detailed calibration procedure see "Address RCP 118 Calibration - ATC Fan Potentiometer" in this section.

119 Interactive Calibration Potentiometer Calibration of Dimmer for Cab Interior Light
Used to calibrate the potentiometer of the dimmer for cab interior light.

NOTE: For detailed calibration procedure see "Address RCP 119 Calibration - Potentiometer of Dimmer For Cab Interior Light" in this section.

150 PWM Output PWM Output 01
Internal Back Lighting (Corner Post)
Possible values: 0 - 100
Value 0 - 0% PWM (min.)
Value 100 - 100% PWM (max.)
151 PWM Output PWM Output 02
External Back Lighting (Overhead Control Panel and Cab Interior Light)
Possible values: 0 - 100
Value 0 - 0% PWM (min.)
Value 100 - 100% PWM (max.)
198 Display - Operator Cutterhead Operating Hours
199 Display - Operator Machine Operating Hours

 

OUZXMAY,0000438 -19-26JUN02-4/4