SIG Addresses - Metal Detector Control Unit
|
|
| SIG - Metal Detector Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 002 |
Standard |
System Beep Mode |
| 003 |
Standard |
Limited System Beep Mode |
| 004 |
Standard |
Analog Beep Mode |
| 005 |
Standard |
Digital Beep Mode |
| 010 |
Analog Input |
Z-X Level Voltage Display in Volts |
| 011 |
Analog Input |
X-Y Level Voltage Display in Volts |
| 012 |
Analog Input |
Y-Z Level Voltage Display in Volts |
| 013 |
Analog Input |
Sensor Reference Voltage Display in Volts |
| 014 |
Analog Input |
Sound Sending Unit A Voltage Display in Volts |
| 015 |
Analog Input |
Sound Sending Unit B Voltage Display in Volts |
| 016 |
Analog Input |
Battery Voltage Display in Volts |
| 017 |
Analog Input |
Battery Voltage 2 Display in Volts |
| 050 |
Digital Input |
Digital Input 01 Following data are transmitted: Release Kernel Processor Belt Tension Output Sense, Driver Power, Sound Sending Unit B Disconnected, Sound Sending Unit A Disconnected, Feedrolls Engaged Output Sense, Quick Stop Switch See also "Address SIG 050 - Digital Input 01" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 080 |
Display |
Sensor Threshold Display Display in mVolts |
| 081 |
Display |
Quick Stop Counter |
| 082 |
Display |
Metal Detector Trip Counter |
|
|
OUZXMAY,000043A -19-01NOV02-1/2
|
| SIG - Metal Detector Control Unit |
| Addresses |
|
| Number |
Type |
Description |
| 100 |
Interactive Calibration |
Metal Detector Engage Used to engage the metal detector simultaneously when the main clutch is engaged.NOTE: For detailed calibration procedure see "Address SIG 100 Calibration - Metal Detector Engage" in this section. |
| 101 |
Input Calibration |
Sensor Initial Threshold Used to set the sensor initial threshold voltage in mV. The initial threshold voltage corresponds to sensor sensitivity height: Value: 925 mV - 2500 mV Display: SIG 101 1500IMPORTANT: The maximum value can not exceed 2500 mV. |
| 102 |
Interactive Calibration |
Failed Stop Pawl Override Used to override a failed stop pawl condition. If this override is active, the metal detector control unit allows the metal detector to arm even if the feedroll stop pawl has failed. ON - Override is not active. OFF - Override is active. Press the OBD calibration switch to toggle the override. Press the OBD calibration switch to set the override based on the operator selection. This override will be disabled when power is removed from the metal detector control unit. Display: SIG 102 ON |
| 139 |
Input Calibration |
Disable 676 Header Processing This address disables processing of 676 header related inputs. 0 - Enables 676 header processing 1 - Disables 676 header processing |
| 140 |
Digital Output |
Digital Output 01 Following data are transmitted: Disengage Feedroll Output, Feedroll Stop Pawl Output, Tension Kernel Processor Belt Output, Header Stop Pawl Output, Self Test X Coil Drive, Self Test Y Coil Drive, Self Test Z Coil Drive See also "Address SIG 140 - Digital Output 01" Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses" |
| 198 |
Display - Operator Calibration - Factory |
Enable Metal Detector Override Counter |
| 199 |
Display - Operator Calibration - Factory |
Pawl Override Counter |
|
|
OUZXMAY,000043A -19-01NOV02-2/2
|
|