SIG Addresses - Metal Detector Control Unit

SIG - Metal Detector Control Unit
Addresses  
Number Type Description
002 Standard System Beep Mode
003 Standard Limited System Beep Mode
004 Standard Analog Beep Mode
005 Standard Digital Beep Mode
010 Analog Input Z-X Level Voltage
Display in Volts
011 Analog Input X-Y Level Voltage
Display in Volts
012 Analog Input Y-Z Level Voltage
Display in Volts
013 Analog Input Sensor Reference Voltage
Display in Volts
014 Analog Input Sound Sending Unit A Voltage
Display in Volts
015 Analog Input Sound Sending Unit B Voltage
Display in Volts
016 Analog Input Battery Voltage
Display in Volts
017 Analog Input Battery Voltage 2
Display in Volts
050 Digital Input Digital Input 01
Following data are transmitted: Release Kernel Processor Belt Tension Output Sense, Driver Power, Sound Sending Unit B Disconnected, Sound Sending Unit A Disconnected, Feedrolls Engaged Output Sense, Quick Stop Switch
See also "Address SIG 050 - Digital Input 01"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
080 Display Sensor Threshold Display
Display in mVolts
081 Display Quick Stop Counter
082 Display Metal Detector Trip Counter

 

OUZXMAY,000043A -19-01NOV02-1/2


SIG - Metal Detector Control Unit
Addresses  
Number Type Description
100 Interactive Calibration Metal Detector Engage
Used to engage the metal detector simultaneously when the main clutch is engaged.

NOTE: For detailed calibration procedure see "Address SIG 100 Calibration - Metal Detector Engage" in this section.

101 Input Calibration Sensor Initial Threshold
Used to set the sensor initial threshold voltage in mV.
The initial threshold voltage corresponds to sensor sensitivity height:
Value: 925 mV - 2500 mV
Display:
SIG
101
1500

IMPORTANT: The maximum value can not exceed 2500 mV.

102 Interactive Calibration Failed Stop Pawl Override
Used to override a failed stop pawl condition.
If this override is active, the metal detector control unit allows the metal detector to arm even if the feedroll stop pawl has failed.
ON - Override is not active.
OFF - Override is active.
Press the OBD calibration switch to toggle the override.
Press the OBD calibration switch to set the override based on the operator selection.
This override will be disabled when power is removed from the metal detector control unit.
Display:
SIG
102
ON
139 Input Calibration Disable 676 Header Processing
This address disables processing of 676 header related inputs.
0 - Enables 676 header processing
1 - Disables 676 header processing
140 Digital Output Digital Output 01
Following data are transmitted: Disengage Feedroll Output, Feedroll Stop Pawl Output, Tension Kernel Processor Belt Output, Header Stop Pawl Output, Self Test X Coil Drive, Self Test Y Coil Drive, Self Test Z Coil Drive
See also "Address SIG 140 - Digital Output 01"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
198 Display - Operator
Calibration - Factory
Enable Metal Detector Override Counter
199 Display - Operator
Calibration - Factory
Pawl Override Counter

 