SPF Addresses - SPFH Main Control Unit

SPF - SPFH Main Control Unit
Addresses  
Number Type Description
002 Standard System Beep Mode
003 Standard Limited System Beep Mode
004 Standard Analog Beep Mode
005 Standard Digital Beep Mode
006 Standard Frequency Beep Mode
010 Analog Input Header Up Valve Current
Display in Amperes
011 Analog Input Header Down Valve Current
Display in Amperes
015 Analog Input Fuel Level Voltage
Display in Volts
016 Analog Input Header Lift Pressure Sensor Voltage
Display in Volts
017 Analog Input Pressure Sensor Power Voltage
Display in Volts
018 Analog Input Header Angle Sensor Voltage
Display in Volts
019 Analog Input IVLOC PWM Current
Display in Amperes
020 Analog Input Battery Voltage
Display in Volts
021 Analog Input Sharpening Potentiometer Power Voltage
Display in Volts
022 Analog Input Sharpening Door Potentiometer Voltage
Display in Volts
023 Analog Input Stone Position Potentiometer Voltage
Display in Volts
024 Analog Input Hydraulic Oil Temperature Sensor Voltage
Display in Volts
025 Analog Input Hydrostatic Oil Temperature Sensor Voltage
Display in Volts
050 Digital Input Digital Input 01
Following data are transmitted: Cutterhead Interlock, Alternator 1, Alternator 2, Right Turn, Left Turn, Header / LOC Neutral, IVLOC Pressure Valid, Main Clutch Switch Off
See also "Address SPF 050 - Digital Input 01"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
051 Digital Input Digital Input 02
Following data are transmitted: Cutterhead Horn 2, Cutterhead Horn 1, Rear Wheel Drive Request, Automatic Lubrication, Hydrostatic Charge Pressure, Multi-Function Lever Neutral, Field Lights
See also "Address SPF 051 - Digital Input 02"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"

 

OUZXMAY,000043B -19-01NOV02-1/6


SPF - SPFH Main Control Unit
Addresses  
Number Type Description
052 Digital Input Digital Input 03
Following data are transmitted: Hazard Light Switch, Seat Switch, Hydraulic Filter Pressure, Powr-Savr Motor Power, Park Brake, Quick Stop Switch, Air Condition High Pressure, Transmission Reverse
See also "Address SPF 052 - Digital Input 03"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
053 Digital Input Digital Input 04
Following data are transmitted: Feedroll Forward Relay Return, Feedroll Switch Forward, Close Sharpen Door, Open Sharpen Door, Manual Cutterhead Reverse, Feedroll Switch Reverse, Feedroll Forward Relay, Transmission Third Gear
See also "Address SPF 053 - Digital Input 04"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
054 Digital Input Digital Input 05
Following data are transmitted: Rotary Air Screen Speed, Left Kernel Processor Clearance, Right Kernel Processor Clearance, Right Stationary Knife Speed, Left Stationary Knife Speed
See also "Address SPF 054 - Digital Input 05"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
070 Frequency Feedroll Speed
Displays the feedroll speed measured in rpm.
071 Frequency Wheel Speed
Displays the wheel speed measured in rpm.
072 Frequency Cutterhead Speed
Displays the cutterhead speed measured in rpm.
080 Display Default Sharpen Sweeps Counter
081 Display Current Sharpen Sweeps Counter
082 Display Sharpen Door Position
083 Display Sharpen Stone Position
084 Display Kernel Processor Clearance Left Motor (Calculated Kernel Processor Clearance)
085 Display Kernel Processor Clearance Right Motor (Calculated Kernel Processor Clearance)
086 Display Stored Engine Speed To Cutterhead Speed Ratio
087 Display Calculated Engine Speed To Cutterhead Speed Ratio
100 Input Calibration Header Type
Used to calibrate the header type for the automatic header control system.
From a raised position lower the header until the header just touches the ground.
Enter this diagnostic address and change the value to match the header type connected to the vehicle.
Following the supported header types:0 = No header selected, Automatic Header Control disabled.1 = Pickup (630A) 950 kg (2095 lb)2 = Pickup (640A, 645A) 1350 kg (2976 lb)3 = 4 Row Row-Crop Unit 1795 kg (3957 lb)4 = 6 Row Row-Crop Unit 2200 kg (4850 lb)5 = 8 Row Row-Crop Unit 2900 kg (6393 lb)6 = 10 Row Row-Crop Unit 3500 kg (7716 lb)7 = Rotary Harvesting Unit (676) 1795 kg (3957 lb)

 

OUZXMAY,000043B -19-01NOV02-2/6


SPF - SPFH Main Control Unit
Addresses  
Number Type Description
101 Interactive Calibration Upper and Lower Header Limit
Used to calibrate the upper limit of the header position.

NOTE: For detailed calibration procedure see "Address SPF 101 Calibration - Upper and Lower Header Limit" in this section.

102 Interactive Calibration Header Raise Rate
Used to calibrate the header raise rate.

NOTE: For detailed calibration procedure see "Address SPF 102 Calibration - Header Raise Rate" in this section.

103 Interactive Calibration Header Lower Rate
Used to calibrate the header lower rate.

NOTE: For detailed calibration procedure see "Address SPF 103 Calibration - Header Lower Rate" in this section.

104 Input Calibration Control Options
Used to calibrate the control options.
Following the control options:To select the kernel processor controlTo indicate the auto lubrication systemKernel Processor Control
1 - Indicates a kernel processor is installed...XX1X
...XXXX
0 - Indicates a kernel processor is not installed...XX0X
...XXXX
Auto Lubrication System
1 - Indicates the auto lubrication system is installed...XXX1
...XXXX
0 - Indicates the auto lubrication system is not installed...XXX0
...XXXX

NOTE: If a kernel processor is installed, the SPFH main control unit enables the kernel processor belt tension interlock for the main clutch.

NOTE: If a kernel processor is not installed, the SPFH main control unit ignores the kernel processor belt tension interlock and shall not allow control of the kernel processor clearance.

NOTE: If the auto lubrication system is installed, the SPFH main control unit sends the status of the auto lubrication system in a CAN status message.

105 Input Calibration Number Of Cutterhead Knifes
Used to read and set the number of knives installed on the cutterhead.
106 Input Calibration Kernel Processor Initial Clearance
Used to read and set the current kernel processor clearance in mm or inch, depends on address RCP 103 settings.
The clearance is settable in 0.1 mm (0.0039 inch.) steps.
107 Input Calibration Auto Actuation Lower Delay
Used to read and set the delay between the feedrolls turning forward and driving the SCV I - output.
The delay is settable in 0.1 second steps.

 

OUZXMAY,000043B -19-01NOV02-3/6


SPF - SPFH Main Control Unit
Addresses  
Number Type Description
108 Interactive Calibration Sharpening Door Closed Position
Used to read and set the closed position of the sharpen door.

NOTE: For detailed calibration procedure see "Address SPF 108 Calibration - Sharpening Door Closed Position" in this section.

109 Interactive Calibration Sharpening Door Open Position
Used to read and set the open position of the sharpen door.

NOTE: For detailed calibration procedure see "Address SPF 109 Calibration - Sharpening Door Open Position" in this section.

110 Interactive Calibration Sharpening Stone Direction Check
Used to verify the sharpening stone motor is wired correctly.

NOTE: For detailed calibration procedure see "Address SPF 110 Calibration - Sharpening Stone Direction Check" in this section.

111 Interactive Calibration Sharpening Stone Home Position
Used to read and set the park position of the sharpening stone.

NOTE: For detailed calibration procedure see "Address SPF 111 Calibration - Sharpening Stone Home Position" in this section.

112 Interactive Calibration Sharpening Stone Left Cutterhead Position
Used to read and set the left cutterhead position of the sharpen stone.

NOTE: For detailed calibration procedure see "Address SPF 112 Calibration - Sharpening Stone Left Cutterhead Position" in this section.

113 Interactive Calibration Sharpening Stone Right Cutterhead Position
Used to read and set the right cutterhead of the sharpening stone.

NOTE: For detailed calibration procedure see "Address SPF 113 Calibration - Sharpening Stone Right Cutterhead Position" in this section.

114 Interactive Calibration Sharpening Stone Advance Position
Used to read and set the advance position of the sharpen stone.

NOTE: For detailed calibration procedure see "Address SPF 114 Calibration - Sharpening Stone Advance Position" in this section.

115 Input Calibration Minimum Cutterhead Speed For Harvesting
Used to read and set the minimum cutterhead speed for harvesting.
116 Interactive Calibration Header Float Raise Rate Calibration
Used to calibrate the header float raise rate.
After entering this address:
Turn the input control knob clockwise to increase the header raise rate.
Turning the input control knob counter-clockwise to decrease the header raise rate.
Press the enter switch to store the value.
117 Interactive Calibration Header Float Lower Rate Calibration
Used to calibrate the header float lower rate.
After entering this address:
Turn the input control knob clockwise to increase the header lower rate.
Turning the input control knob counter-clockwise to decrease the header lower rate.
Press the enter switch to store the value.

 

OUZXMAY,000043B -19-01NOV02-4/6


SPF - SPFH Main Control Unit
Addresses  
Number Type Description
119 Interactive Calibration Override 676 Header Check
Used to override the 676 header check.
0 - enables processing of 676 header inputs:Feedroll control, based on the 676 header inputsGeneration of all 676 header related DTCs1 - allows operation of a header under conditions where there is a deviation from normal operation.
Default value: Zero, each time power to the SPFH main control unit is cycled.
140 Digital Output Digital Output 01
Following data are transmitted: Left Kernel Processor Away, Right Stationary Knife Away, Right Stationary Knife In, Left Stationary Knife Away, Left Stationary Knife In, Stone Sweep Out, Stone Sweep In, Right Kernel Processor In
141 Digital Output Digital Output 02
Following data are transmitted: Header Up Valve Current And Header Down Valve Current Return Disable, IVLOC PWM Current Return Disable, Sharpen Door Close, Sharpen Door Open, Left Kernel Processor In
See also "Address SPF 140 - Digital Output 01"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
142 Digital Output Digital Output 03
Following data are transmitted: Feedroll Forward Relay Return Disable, Right Kernel Processor Away, Header Speed Slow, Header Speed Fast, Gear Lock, Engage Feedrolls Forward, Reverse Feedrolls, Powr-Savr Interlock Relay Return Disable
See also "Address SPF 142 - Digital Output 03"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
143 Digital Output Digital Output 04
Following data are transmitted: IVLOC Enable, Managed Power
See also "Address SPF 143 - Digital Output 04"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
144 Digital Output Digital Output 05
Following data are transmitted: Cutterhead Horn 1, Right Turn Lamp, Left Turn Lamp, Cutterhead Horn 2, Vehicle Turn, North American Stop Lamp, Hazard Switch Lamp
See also "Address SPF 144 - Digital Output 05"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
145 Digital Output Digital Output 06
Following data are transmitted: Left Worklight, Right Worklight, Spout Cap Down, Spout Cap Up, Accumulator Shutoff, Liquid Injection Pump, Reel Speed Increase, Reel Speed Decrease
See also "Address SPF 145 - Digital Output 06"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
146 Digital Output Digital Output 07
Following data are transmitted: Field Mode Operation, Spout Rotate Fast, Spout Rotate Right, Spout Rotate Left, 676 Header Brake, Air Condition Clutch, Trailer Up, Trailer Down
See also "Address SPF 146 - Digital Output 07"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"
147 Digital Output Digital Output 08
Following data are transmitted: Cutterhead Safety Interlock Relay Return Disable, Selective Control Valve I Port B, Selective Control Valve I Port A, Selective Control Valve II Port A, Selective Control Valve II Port B, Unload Valve, Spout Raise, Spout Lower
See also "Address SPF 147 - Digital Output 08"
Entering OBD-Addresses see "On-Board Diagnostic - Entering Addresses"

 

OUZXMAY,000043B -19-01NOV02-5/6


SPF - SPFH Main Control Unit
Addresses  
Number Type Description
150 PWM Output Header Up
(X - 10 = represents 10 percent of PWM applied to the output)
151 PWM Output Header Down
(X - 10 = represents 10 percent of PWM applied to the output)
152 PWM Output IVLOC Positive PWM
(X - 10 = represents 10 percent of PWM applied to the output)
153 PWM Output IVLOC Negative PWM
(X - 10 = represents 10 percent of PWM applied to the output)
198 Display - Operator Cutterhead Operating Time
199 Display - Operator Machine Operating Time

 

OUZXMAY,000043B -19-01NOV02-6/6