| OCP - Overhead Control Panel Control Unit Diagnostic Trouble Codes |
| Control Unit |
SPN |
FMI |
Pri. |
Indicator Light |
Description |
Effect |
| OCP |
158 |
00 |
2 |
|
Battery Voltage High indicates that the system battery voltage input to the overhead control panel control unit is above 16 volts. |
Control Unit shutdown, Control unit functions not available. |
| OCP |
158 |
01 |
2 |
|
Battery Voltage Low indicates that the system battery voltage input to the overhead control panel control unit is below 10.5 volts. |
Control Unit shutdown, Control unit functions not available. |
| OCP |
623 |
05 |
2 |
|
Red Stop Lamp Failure indicates that the overhead control panel control unit detects the indication lamp driver fault input is inactive AND red lamp is inactive (OFF) AND remaining lamps are active (ON). This diagnostic trouble code is sent during the power on test period only. |
Red stop lamp is not available to signalize a stop lamp failure. |
| OCP |
624 |
05 |
3 |
|
Amber Warning Lamp Failure indicates that the overhead control panel control unit detects the indication lamp driver fault input is inactive AND amber warning lamp is inactive (OFF) AND remaining lamps are active (ON). This diagnostic trouble code is sent during the power on test period only. |
Warning lamp is not available to signalize a warning lamp failure. |
| OCP |
628 |
12 |
2 |
|
Program Memory Failure indicates that control unit boot block detects that the application software is not executing (generated by the boot block) |
Control unit function not available. |
| OCP |
987 |
05 |
2 |
|
Protect Lamp Failure indicates that the overhead control panel control unit detects the indication lamp driver fault input is inactive AND protect lamp is inactive (OFF) AND remaining lamps are active (ON). This diagnostic trouble code is sent during the power on test period only. |
Protect lamp is not available to signalize a protect lamp failure. |
| OCP - Overhead Control Panel Control Unit Diagnostic Trouble Codes |
| Control Unit |
SPN |
FMI |
Pri. |
Indicator Light |
Description |
Effect |
| OCP |
300302 |
12 |
2 |
|
Powr-Savr Switch Component Failure indicates that the overhead control panel control unit detects any of the powr-savr switches (kernel processor adjust, kernel processor adjust abort, stationary knife adjust, stationary knife away, cutterhead sharpen or home position) are pressed AND the interlock relay driver input is inactive (low). |
Internal problem to conrol the Powr-Savr interlock relay output, no Powr-Savr motor power available. |
| OCP |
300303 |
03 |
2 |
|
Powr-Savr Interlock Relay Failure To Open (Powr-Savr Motor Power Detected) indicates that the overhead control panel control unit receives a CAN message that indicates a powr-savr function is inactive AND the control panel detects powr-savr motor power (powr-savr motor power input is active (high) for longer than 500 ms). |
Relay failure. |
| OCP |
300303 |
04 |
2 |
|
Powr-Savr Interlock Relay Failure To Close (No Powr-Savr Motor Power) indicates that the overhead control panel control unit receives a CAN message that indicates a powr-savr function is active AND the control panel detects no powr-savr motor power (powr-savr motor power input is inactive (low) for longer than 500 ms). |
No Powr-Savr motor power. Powr-Savr function can not be performed. |
| OCP |
300305 |
03 |
2 |
|
Kernel Processor Adjust Switch Failure indicates that the overhead control panel control unit detects the kernel processor adjust switch is pressed continuously for 1 minute. |
Probably kernel processor adjust switch does not work correctly. |
| OCP |
300306 |
03 |
2 |
|
Kernel Processor Adjust Abort Switch Failure indicates that the overhead control panel control unit detects the kernel processor adjust abort switch is pressed continuously for 1 minute. |
Probably kernel processor adjust abort switch does not work correctly. |
| OCP |
300307 |
03 |
2 |
|
Stationary Knife Away Switch Failure indicates that the overhead control panel control unit detects the stationary knife away switch is pressed continuously for 2 minutes. |
Probably stationary knife away switch does not work correctly. |
| OCP - Overhead Control Panel Control Unit Diagnostic Trouble Codes |
| Control Unit |
SPN |
FMI |
Pri. |
Indicator Light |
Description |
Effect |
| OCP |
300308 |
03 |
2 |
|
Stationary Knife Adjust Switch Failure indicates that the overhead control panel control unit detects the stationary knife adjust switch is pressed continuously for 1 minute. |
Probably stationary knife adjust switch does not work correctly. |
| OCP |
300309 |
03 |
2 |
|
Home Position Switch Failure indicates that the overhead control panel control unit detects the home position switch is pressed continuously for 1 minute. |
Probably home position switch does not work correctly. |
| OCP |
300310 |
03 |
2 |
|
Cutterhead Sharpen Switch Failure indicates that the overhead control panel control unit detects the cutterhead sharpen switch is pressed continuously for 1 minute. |
Probably cutterhead sharpen switch does not work correctly. |
| OCP |
300311 |
05 |
|
|
Indicator Lamp Failure indicates if any one of the indicator lamps fails during the run time, after Power On test period. |
|
| OCP |
300312 |
04 |
2 |
|
Row Guidance Enable / Disable Switch Failure indicates that the overhead control panel control unit detects the row guidance enable / disable switch is pressed continuously for 1 minute. |
Probably row guidance enable / disable switch does not work correctly. |
| OCP |
300313 |
04 |
2 |
|
Metal Detector Calibrate Switch Failure indicates that the overhead control panel control unit detects the metal detector calibrate switch is pressed continuously for 1 minute. |
Probably metal detector calibrate switch does not work correctly. |
| OCP |
300314 |
04 |
2 |
|
Metal Detector Test Switch Failure indicates that the overhead control panel control unit detects the metal detector test switch is pressed continuously for 1 minute. |
Probably metal detector test switch does not work correctly. |
| OCP |
300315 |
04 |
2 |
|
Metal Detector Enable Switch Failure indicates that the overhead control panel control unit detects the metal detector enable switch is pressed continuously for 1 minute. |
Probably metal detector enable switch does not work correctly. |