RCP - Corner Post Control Unit Diagnostic Trouble Codes

RCP - Corner Post Control Unit Diagnostic Trouble Codes
Control Unit SPN FMI Pri. Indicator Light Description Effect
RCP 158 00 2   Battery Voltage High indicates that the system battery voltage input to the corner post control unit is above 16 volts. Control Unit shutdown, Control unit functions not available.
RCP 158 01 2   Battery Voltage Low indicates that the system battery voltage input to the corner post control unit is below 10.5 volts. Control Unit shutdown, Control unit functions not available.
RCP 628 12 2   Program Memory Failure indicates that the control unit boot block detects that the application software is not executing (generated by the boot block). Control unit functions not available.
RCP 1500 11 2   Corner Post Matrix Switch indicates that there is a problem with the corner post matrix switch panel. A key may be stuck or another problem exists within the corner post matrix switch. One or probably several switches of the corner post don't work correctly.
RCP 1552 03   Air temperature control Temperature Set Point Potentiometer High indicates that switch is in the on OR defog position AND the sensor voltage input is above 4.5 volts. Temperature setting not possible.
RCP 1552 04   Air temperature control Temperature Set Point Potentiometer Low indicates that switch is in the on OR defog position AND the sensor voltage input is below 0.5 volts. Temperature setting not possible.
RCP 1552 13 3 Air temperature control Temperature Set Point Potentiometer Not Calibrated indicates that switch is in the on OR defog position AND the EEPROM indicates that the calibration was not done OR the value is out of max. / min. value. Temperature setting not possible.
RCP 1553 03   Air temperature control Blower Setting Potentiometer High indicates that switch is in the on OR defog position AND the sensor voltage input is above 4.5 volts. Blower setting not possible.
RCP 1553 04   Air temperature control Blower Setting Potentiometer Low indicates that switch is in the on OR defog position AND the sensor voltage input is below 0.5 volts. Blower setting not possible.

 

OUZXMAY,00005C0 -19-13OCT02-1/3


RCP - Corner Post Control Unit Diagnostic Trouble Codes
Control Unit SPN FMI Pri. Indicator Light Description Effect
RCP 1553 13 3 Air temperature control Blower Setting Potentiometer Not Calibrated indicates that switch is in the on OR defog position AND the EEPROM indicates that the calibration was not done OR the value is out of max. / min. value. Blower setting not possible.
RCP 300400 09 2   Metal Detector Control Unit Not Communicating indicates that the corner post control unit has not received a message from the metal detector control unit in the last 5 seconds. Metal detector control functions not available, harvesting operations not possible.
RCP 300401 09 2   Armrest Control Unit Not Communicating indicates that the corner post control unit has not received a message from the armrest control unit in the last 5 seconds. Corner post control unit functions not availble.
RCP 300402 09 2   SPFH Main Control Unit Not Communicating indicates that the corner post control unit has not received a message from the SPFH main control unit in the last 5 seconds. SPFH main control unit functions not available, harvesting operations not possible.
RCP 300403 09 2   Overhead Control Panel Control Unit Not Communicating indicates that the corner post control unit has not received a message from the overhead control panel control unit in the last 5 seconds. Overhead control panel control unit functions not available.
RCP 300404 09 2   Rear Wheel Drive Control Unit Not Communicating indicates that the corner post control unit has not received a message from the rear wheel drive control unit in the last 5 seconds AND the rear wheel drive enable request is received from the SPFH control unit. Rear wheel drive disabled.
RCP 300405 09 2   Row Guidance Control Unit Not Communicating indicates that the corner post control unit has not received a message from the row guidance control unit in the last 5 seconds AND the row guidance enable request is received from the overhead control panel control unit. Row guidance control unit disabled.
RCP 300406 03     Backlight Dimmer Potentiometer High indicats that the lights are on AND the output of the potentiometer voltage is above 4.5 volts. Default backlight to on.

 

OUZXMAY,00005C0 -19-13OCT02-2/3


RCP - Corner Post Control Unit Diagnostic Trouble Codes
Control Unit SPN FMI Pri. Indicator Light Description Effect
RCP 300406 04     Backlight Dimmer Potentiometer Low indicats that the lights are switched on AND the output of the potentiometer voltage is below 0.5 volts. Default backlight to on.
RCP 300406 13 3   Backlight Dimmer Potentiometer Not Calibrated indicates that the lights are on AND the EEPROM indicates that the calibration was not done OR value is out of max. / min. value. Default backlight to on.

 

OUZXMAY,00005C0 -19-13OCT02-3/3